User Guide

Maintenance Kits
Mineral Reducer Kit
Order #: AVA8200
Includes:
Installation instructions, housing,
cartridge, all necessary mounting
and installation hardware.
Order #: PFM8200
Includes:
• Cartridge for Mineral Reducer.
ADP
Vacuum Relief Valve Filter
Order #: 62935601
Includes:
• Filter
Vacuum Inlet Strainer
Order #:
Single Models - 62937301
Twin Models - 77005155
Includes:
• Filter bowl, screen and o-ring.
Dispos-A-Bowl
Order #:
Single Models - 77005167
Twin Models - 77005168
Includes:
• Container, lid and red safety tape.
Exhaust Silencer
Order #: 77000040
Includes:
• Single Vacs Only
Accessories
Vacuum
Inlet
Strainer
Water
Inlet
Strainer
Water
By-Pass
Valve In
Open
Position
Recycler
Models
Non-Recycler
Models
For Recycler To Be
Activated
During Normal
Operation The Water
By-Pass Valve Should
Be In the CLOSED
postion.
Recycler
Models
CLOSED Position
Shown
Note - Recycler Models Only
If you have low to no suction due to a clog by residue building up over time, there is a feature on vacuum to keep
it running until a service technician can troubleshoot the problem. Turn the water by-pass valve to the OPEN
position. This will by-pass the recycler and may keep the pump running.
© 2020 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1.800.643.6275 | 1.937.526.3662 | www.midmark.com
Daily
A. Clean Vacuum Piping System.
Clean piping system with a non-foaming vacuum
system cleaner. Midmark recommends
Precision Clense™, Order No. 77000570.
Note:ForthersttwoweeksofusingPrecision
Clense,ushlinesatthebeginningofthedaywith
waterandchecktrapstwiceaday.Afterthersttwo
weeks,ushwithwaterandchecktrapsasneeded.
1) Start with the furthest operatory from the vacuum.
2) Suction cleaning solution.
(Follow mixture instructions provided with the
vacuum system cleaner.)
Note: Alternate air and vacuum while cleansing;
submerge and remove HVE and SE from mixture
several times until mixture is consumed.
3) Keep the cleansed vacuum lines (HVE and SE)
open and move to the next operatory.
4) Repeat steps 1-3 until all vacuum lines are
cleansed.
B. Clean Vacuum Inlet Strainer.
Turn vacuum “OFF”. Remove, replace and or clean
lterbowl,screenandgasket.Reassemble.Turn
vacuum “ON”.
Annually
A. Clean and or Replace Vacuum Relief
Filter.
Pulllteroutofendcap.Blowolterandor
replaceifdamaged.ReplacelterinVRVendcap.
B. Clean Water Inlet Strainer.
Turn vacuum “OFF”. Remove cap on “Y” strainer
housing and pull out the wire intake strainer.
Rinsewithwaterandblowo.Replacestrainer
and cap. Turn vacuum “ON”.
C. Clean / Dust Vacuum Pump(s).
Wipe with a clean cloth to remove dust and debris.
Equipment Alert
Scavenging polishing paste with
abrasives, running the pump with
no water supplied, using water with high mineral
content, or water with excessive sediment can
damage or reduce the lifespan of the pump and is
not considered a defect in material or workmanship.

Summary of content (2 pages)