V. Asset Tracking Sensor Placement Guidelines
A. Use the following guidelines for sensor placement in an
available 110v outlet:
• The distance between sensors should be less than 25 feet
• The height from the floor should be between 1 and 12 feet in a wall
mounted receptacle
• Room sensor placement preference is away from corridors and room entry doors
• Corridor sensor placement preference is away from doors for rooms with a sensor
• Sensors should be 9 to 30 feet away from floor transitions (e.g., stairs, escalators,
and elevators)
VI. Controlling Relay
A. For the initial release of the sensor, the relay is set to the
on state with no option to control it.
When relay is set, power is passed through.