Operating Instructions
Clear Settings
To clear all of the R8’s settings, send it the following System Exclusive
programming message:
F0 00 00 50 26 00 F7 (all values in Hexadecimal)
It is advisable to send the Clear Settings command to the R8 prior to
programming the unit to insure that all previous settings are cleared.
Dump Settings
To dump all of the R8’s current settings, send it the following System
Exclusive message:
F0 00 00 50 26 10 F7 (all values in Hexadecimal)
Upon receipt of this command the R8 will dump all of its current settings to
its MIDI Out.
Link Settings
To link together all of the Note and Controller settings of a given relay,
send the R8 the following System Exclusive programming message:
F0 00 00 50 26 05 rr aa F7 (all values in Hexadecimal)
rr = relay# (00 for Rel1 through to 07 for Rel8)
aa is set as follows:
aa = 00: Link OFF - each Note and Controller setting for that relay
operates independently
aa = 01: CLOSED Link - Relay closes only if conditions of all Note
and Controller settings for that relay are in
the closed state
aa = 02: OPEN Link - Relay opens only if conditions of all Note and
Controller settings for that relay are in the
open state
6