Use and Care Guide
!%
PERFORMANCE DATA SHEET
WATER FILTRATION SYSTEM
MODEL MF-2008-R2 CAPACITY 200 GALLONS (757 LITERS)
System tested and certified by NSF International against 
NSF/ANSI Standards 42 and 53 for the reduction of contaminants 
specified on the Performance Data Sheet.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction 
of the substances listed below. The concentration of the indicated substances in water 
entering the system was reduced to a concentration less than or equal to the permissible 
limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction Influent challenge 
concentration 
(mg/L)
Maximum permissible 
product water 
concentration (mg/L)
Avg % 
Reduction
NSF 
Reduction 
Requirements
Chlorine Reduction
2.0 mg/L ± 10% NA 93.7% 50%
Particulate 
Reduction, Class I*
*10000/ml NA >99.9% *85%
Lead Reduction 
0.15mg/L ± 10% )0.010 99.60% NA
Live Cysts†
50000/L NA >99.99% 99.95%
Test Parameters: pH = 7.69 ± 0.5 unless otherwise noted. Flow = 0.52 gpm (1.89 Lpm).
Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
•
It is important that operational,
maintenance, and filter replacement
requirements be carried out for the
product to perform as advertised.
Property damage can occur if all
instructions are not followed.
•
The disposable cartridge must be
changed at least every 6 months.
•
Use replacement filter MF-2008-R2.
•
The filter monitor system measures the
amount of water that passes through
the filter and alerts you when it is time
to replace the filter. See “Using the
Controls.”
•
After changing the water filter, flush the
water system. See “Dispenser.”
•
These contaminants are not necessarily
in your water supply. While testing was
performed under standard laboratory
conditions, actual performance may
vary.
•
The product is for cold water use only.
•
The water system must be installed in
compliance with state and local laws
and regulations.
•
Do not use with water that is
microbiologically unsafe or of unknown
quality without adequate disinfection
before or after the system. Systems
certified for cyst reduction may be used
on disinfected waters that may contain
filterable cysts. EPA Est. No. 10350-MN-
005.
•
Refer to the “Warranty” section for the
Manufacturer’s limited warranty, name
and telephone number.
Application Guidelines/ 
Water Supply Parameters
Water Supply Potable City or Well
Water Pressure 35 - 120 psi 
(241 - 827 kPa)
Water 
Temperature
33° - 100°F 
(1° - 38°C)
Service Flow 
Rate
0.52 gpm (1.89 L/min.) 
 @ 60 psi
* Class I particle size: >0.5 to <1 μm.
†
 Based on the use of Cryptosporidium parvum 
oocysts.
®
 NSF is a registered trademark of NSF 
International.