User Manual
6
Hook the hood body
● Hook the hood body to the bracket 20.
● Level the hood body itself.
● Lock screws (M5*12) into the hood xing bracket to prevent the hood body from accidentally
sliding off. Remove the lter from the inside of the hood body, and x the screw 10 to wall plug 11
at the point (3) (optional).
When installing the ducted version, connect the hood to the chimney
using either a exible or a rigid pipe of ɸ 150 or ɸ 120 mm, the choice
of which is left to the installer.
● Insert the reducer ange 3 onto the hood body outlet to install a ɸ
120 mm air exhaust connection.
● Fix the pipe 4 in place using sufcient pipe clamps (not supplied).
● Remove possible charcoal lters.
Lower decorative chimney
● Fix the chimney xing bracket 21 onto the lower decorative chimney with 2 screws 12 (4.2 x 9.5)
supplied with the hood.
Upper decorative chimney
● Insert the upper decorative chimney 2.2 into the lower decorative chimney 2.1 and drag it up
to the bracket 21.
● Fix the upper chimney onto the bracket 21 with 2 screws 12 (4.2 x 9.5) supplied with the hood.
CONNECTIONS
CHIMNEY ASSEMBLY
DUCTED VERSION AIR EXHAUST SYSTEM
The chimney can only be installed with an exhausting hood.
21
2.1
12