User Manual
6
● Mark a point (3) on the horizontal line C, 130 (250 optional) mm to the vertical reference line.
● Repeat this operation on the other side, checking that the two marks are on one horizontal line.
Fix the brackets (optional):
● Drill holes at the marked points with a ɸ10 mm drill bit.
● Insert the wall plugs 11 into the holes.
● Fix the hood xing bracket 20 with 3 screws 10 (5 x 50) at the horizontal line A,
● Fix the chimney xing bracket 21 with 2 screws 10 (5 x 50) at the horizontal line B.
Hook the hood body:
● Open the panel.
● Remove the metal grease lter using the handles provided.
● Hook the hood body to the bracket 20.
● Level the hood body itself.
● From the inside of the hood body, x the screw 10 to wall plug 11 at the point (3).
● Fit the lter into the hood.
● Close the panel.
CONNECTIONS
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney
using either a exible or a rigid pipe of ɸ 150 or ɸ 120 mm, the choice
of which is left to the installer.
● Insert the reducer ange 3 onto the hood body outlet to install a ɸ
120 mm air exhaust connection.
● Fix the pipe 4 in place using sufcient pipe clamps (not supplied).
● Remove possible charcoal lters.