INSTALLATION MANUAL Floor-Standing Type Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference.
If used as MULTI unit, please refer to the Installation & operation manuals packed with outdoor unit.
CONTENTS PAGE PRECAUTIONS.......................................................................................1 INSTALLATION INFORMATION............................................................... 2 ACCESSORIES ....................................................................................3 INSPECTING AND HANDLING THE UNIT.................................................4 Install according to this installation instructions strictly.
If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into the place contacting with fire. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. After completing the installation work, check that the refrigerant does not leak.
3. ACCESSORIES Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully. Table 3-1 NAME Installation fittings SHAPE QUANTITY 1.Hook 2 2. Remote controller 1 3. Frame 1 4. Mounting screw(ST2.9×10-C-H) 2 5. Alkaline dry batteries (AM4) 2 6. Owner's manual 1 7. Installation manual 1 Remote controller & Its Frame Others 8 .Transfer connector( 9.52- 12.
4. INSPECTING AND HANDLING THE UNIT At delivery, the package should be checked and any damage should be reported immediately to the service agent. 700mm 210mm When handling the unit, take into account the following: 1 Fragile, handle the unit with care. Keep the unit upright in order to avoid compressor damage. 2 Choose on before hand the path along which the unit is to be brought in. 3 Move this unit as originally package as possible.
6. OUTDOOR UNIT INSTALLATION 6.1 Installation Place The outdoor unit should be installed invvv the location that meets the following requiements: There is enough room for installation and maintenance. The air outlet and the air inlet are not impeded, and can not be reached by strong wind. It must be a dry and well ventilating place. The support is flat and horizontal and can stand the weight of the outdoor unit. And will no additional noise or vibration.
Side air outlet outdoor unit 7. INSTALL THE CONNECTING PIPE (Wall or obstacle) Check whether the height drop between the indoor unit and outdoor unit, the length of refrigerant pipe, and the number of the bends meet the following requirements: Air inlet >30cm Table 7-1 N Air inlet Capacity(Btu/h) 12000 16000~18000 >60cm The max height drop 5m 10m P The length of refrigerant pipe Less than 10m Less than 20m The number of bends Less than 5 Less than 8 Maintain channel M Air outlet Fig.
How to take indoor unit apart to connect the pipes 1 Open the frant panel Slide the two stoppers on the left and right sides inword until they click .(Refer to Fig.7-1) Fig.7-3 How to take outdoor unit apart to connect the pipes Remove the water tray(Refer to Fig.7-4) Fig.7-1 2 Remove the front panel . Remove the string.(Refer to Fig.7-2) Allowing the front panel to fall forward will enable you to remove it. Water tray Fig.7-4 How to Connect the pipes 1 Flaring Cut a pipe with a pipe cutter.
2 Connect the indoor unit at first, then the outdoor unit. Table 7-3 Bend the tubing in proper way. Do not harm to them. Stop Valve size Bend the pipe with thumb Tightening torque N M (Turn clockwise to close) Ø6.35 Ø9.52 Ø12.7 min-radius 100mm Ø15.9 Fig.7-6 5.4~6.6 Hexagonal wrench 4 mm Ø25.4 18~22 Hexagonal 13.5~16.5 wrench 6 mm 27~33 Bending position is preferably in the middle of the bendable pipe. The larger the bending radius the better it is. Maintenance nut 13.5~16.5 8.1~9.9 Ø22.
8. CONNECT THE DRAIN PIPE Manifold valve Multi-meter Pressure meter Install the drainpipe of the indoor unit -76 cmHg Lo-lever Hi-lever Charge hose Charge hose The outlet has PTI screw bread, Please use sealing materials and pipe sheath(fitting) when connecting PVC pipes. Vacuum pump CAUTION Fig.7-11 Lo-lever The drain pipe of indoor unit must be heat insulated, or it will condense dew, as well as the connections of the indoor unit.
4 For power details of the air conditioner refer to the rating plate of the product. 5 For any question contact your local dealer. 9.1 Connect the cable Seal Drain joint The base pan hole of outdoor unit The installation bearer of sensing device rotated to another side, and then takes off cover of electrical box. (Take off the electrical box if the capacity is 18000btu/h as well as using network function.) (Refer to Fig.
Connect the connective cables to the terminals as identified with their respective mached numbers on the terminal block of indoor and outdoor units. 10. TEST OPERATION 1 The test operation must be carried out after the entire installation has been completed. 2 Please confirm the following points before the test operation: Re-install the Indoor unit and outdoor unit 9.2 The Specification of Power The indoor unit and outdoor unit are installed properly.
The Specification of Power Table 9-2 12000Btu/h (Cooling & Heating) TYPE PHASE POWER 1-PHASE FREQUENCY AND VOLT CIRCUIT BREAKER/FUSE 16000~18000Btu/h (Cooling & Heating) 208-240V~, 50Hz/60Hz 208-240V~, 50Hz/60Hz (A) 20/16 2 INDOOR UNIT POWER WIRING(mm ) (mm2) OUTDOOR UNIT POWER WIRING STRONG ELECTRIC SIGNAL WEAK ELECTRIC SIGNAL 20/16 3x1.0 GROUND WIRING INDOOR/OUTDOOR CONNECTING WIRING 1-PHASE 1.5 2.5 3X1.5 3x2.5 4X1.0 3X0.
Fig.9-5 Power supply Switch/Fuse (Available locally) Power wiring (outdoor) Power linking wiring (indoor) Indoor Unit Outdoor Unit Ground wiring Strong elec-signal link wiring Ground wiring Weak elec-signal link wiring Ground the air conditioner properly in case to affect its anti-interference function Fig.
Fig.9-7 Power supply Switch/Fuse (Available locally) Power wiring (outdoor) Indoor Unit Outdoor Unit Ground wiring Strong elec-signal link wiring Ground wiring Weak elec-signal link wiring Ground the air conditioner properly in case to affect its anti-interference function CAUTION A disconnection device having an air gap contact separation in all active conductors should be incorporated in the fixed wiring according to the National Wiring Regulation.