Installation Instructions
4
installation manual
5. INDOOR UNIT INSTALLATION
4. INSPECTING AND HANDLING THE UNIT
At delivery, the package should be checked and any damage should
be reported immediately to the carrier claims agent.
When handling the unit, take into account the following:
Fragile, handle the unit with care.
Keep the unit upright in order to avoid compressor
damage.
Choose on before hand the path along which the unit is to be
brought in.
Move this unit as originally package as possible.
When lifting the unit , always use protectors to prevent belt
damage and pay attention to the position of the unit’s centre of
gravity.
1
2
3
4
Keep indoor unit, outdoor unit, power supply wiring and
transmission wiring at least 1 meter away from televisions
and radios. This is to prevent image interference and
noise in those electrical appliances. (Noise may be
generated depending on the conditions under which the
electric wave is generated, even if 1 meter is kept.)
There is enough room for installation and maintenance.
(refer to Fig.5-1 and Fig.5-2)
The outlet and the inlet are not impeded, and the
influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out
easily.
There is no direct radiation from heaters.
5.1 Installation place
5.2 Install the main body
The indoor unit should be installed in a location that meets
the following reauirements:
CAUTION
Fig.5-1
Fig.5-2
Fig.5-3
Fig.5-4
Fix the hook with tapping screw onto the wall.(refer to Fig.5-3)
Hang the indoor unit on the hook.
(The bottom of body can touch with floor or suspended, but the
body must install vertically.)
≥100mm
195mm
1
9
5
m
m
≥100mm
≥100mm
Hook
Hook
Tapping
screw
Washer
mm
≥1000mm
700mm
210mm
600mm