INSTALLATION MANUAL Floor Standing Type Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference. PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
CONTENTS PAGE PRECAUTIONS.......................................................................................1 INSTALLATION INFORMATION............................................................... 2 ACCESSORIES ....................................................................................3 INSPECTING AND HANDLING THE UNIT.................................................4 INDOOR UNIT INSTALLATION.................................................................4 OUTDOOR UNIT INSTALLATION.........
2. If the refrigerant leaks during installation, ventilate the area immediately. Toxic gas may be produced if the refrigerant comes into the place contacting with fire. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tub. After completing the installation work, check that the refrigerant does not leak.
3. ACCESSORIES Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully. NAME Installation fittings SHAPE QUANTITY 1.Hook 2 2. Remote controller 1 3. Frame 1 Remote controller & Its Frame 4. Mounting screw(ST2.9 10-C-H) 2 5. Alkaline dry batteries (AM4) 2 6. Owner's manual 1 7. Installation manual 1 Others Cautions on remote controller installation: Never throw or beat the controller.
4. INSPECTING AND HANDLING THE UNIT At delivery, the package should be checked and any damage should be reported immediately to the carrier claims agent. 700mm 210mm When handling the unit, take into account the following: Fragile, handle the unit with care. 1 2 Choose on before hand the path along which the unit is to be brought in. 3 Move this unit as originally package as possible.
6. OUTDOOR UNIT INSTALLATION 6.1 Installation Place H The outdoor unit should be installed in the location that meets the following requiements: There is enough room for installation and maintenance. The air outlet and the air inlet are not impeded, and can not be reached by strong wind. It must be a dry and well ventilating place. The support is flat and horizontal and can stand the weight of the outdoor unit. And will no additional noise or vibration.
1 Drill a hole in the wall (suitable just for the size of the wall conduit), then set on the fittings such as the wall conduit and its cover. 2 Bind the connecting pipe and the cables together tightly with binding tapes. Pass the bound connecting pipe through the wall conduct from outside. Be careful of the pipe allocation to do on damage to the tubing. Do not lean it more than 45, and do not lay it sidelong. 3 Connect the pipes. Refer to "How to Connect the pipes" for details.
2 Remove the front panel . Remove the string.(refer to Fig.7-2) Allowing the front panel to fall forward will enable you to remove it. Water tray Fig.7-4 Fig.7-2 3 Remove the face plate . Remove the four screws.(refer to Fig.7-2) Opening bottom of face plate for a angle that is 30 degrees, then the top of face plate will be take up.(refer to Fig.7-3) How to Connect the pipes 1 Flaring Cut a pipe with a pipe cutter. (Refer to Fig.7-6) 90 Lean crude burr Fig.
2 Connect the indoor unit at first, then the outdoor unit. 2. Closing stop valve 1. Remove the cap and turn the valve clockwise with the hexagon wrench. Bend the tubing in proper way. Do not harm to them. 2. Securely tighten the valve until the shaft contacts the main bodyseal. Bend the pipe with thumb Make sure to tighten the cap securely. For the tightening torque,refer to the table below. min-radius 100mm Fig.7-6 Ta ble 7-3 The bending angle should not exceed 90.
Outdoor unit 8. Indoor unit A Gas side CONNECT THE DRAIN PIPE C Install the drainpipe of the indoor unit Liquid side D B The outlet has PTI screw bread, Please use sealing materials and pipe sheath(fitting) when connecting PVC pipes. Stop valve Fig.7-10 CAUTION Manifold valve Multi-meter Pressure meter The drain pipe of indoor unit must be heat insulated, or it will condense dew, as well as the connections of the indoor unit.
Inatall the drain joint of the outdoor unit Fit the seal into the drain joint, then insert the drain joint into the base pan hole of outdoor, rotate 90 to securely assemble them. Connect the drain joint with an extension drain hose (Locally purchased), in case of the condensate draining off the outdoor unit during the heating mode.(Refer to Fig.
Connect the connective cables to the terminals as identified with their respective mached numbers on the terminal block of indoor and outdoor units. 10. TEST OPERATION 1 The test operation must be carried out after the entire installation has been completed. 2 Please confirm the following points before the test operation: Re-install the Indoor unit and outdoor unit 9.2 The Specification of Power The indoor unit and outdoor unit are installed properly.
The Specification of Power Table 9-1 12000Btu/h (Cooling Only) TYPE(for R22) POWER PHASE 1-PHASE FREQUENCY AND VOLT 220-240V~, 50Hz (A) 20/16 INDOOR UNIT POWER WIRING(mm ) 3x1.5 CIRCUIT BREAKER/FUSE 2 GROUND WIRING INDOOR/OUTDOOR CONNECTING WIRING (mm2) 18000Btu/h (Cooling Only) 1-PHASE 220-240V~, 50Hz 20/16 1.5 OUTDOOR UNIT POWER WIRING STRONG ELECTRIC SIGNAL WEAK ELECTRIC SIGNAL 2.5 3x2.5 3X1.5 3X0.5 Wiring figure Installing wiring chart, refer to link circuit chart for details.
CAUTION When wiring, please choose the corresponding chart, or it may cause damage. INDOOR UNIT XT1 L N S POWER: 220-240V 50Hz L N S OUTDOOR UNIT 3-core cable 3x1.5mm 2 4-core cable 3x1.5mm 2 12000Btu/h(1 PHASE) Air Conditioner Link-circuit (For R410a,Cooling& Heating) Fig.9-3 INDOOR UNIT L XT1 P Q E 2 OUTDOOR UNIT 3-core shield wire 3x0.5mm N 3-core cable 3x2.5mm 2 POWER: 220-240V 50Hz 18000Btu/h(1 PHASE) Air Conditioner Link-circuit (For R410a ,Cooling& Heating) Fig.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.
PDF 文件使用 "pdfFactory Pro" 试用版本创建 www.fineprint.