Manual

Beforecalling for service, review
PROBLEM
Unit does not start
Dehumidifier does not
dry the air as it should
The unit makes a loud
noise when operating
Frost appears on the coils
Water on floor
Drain hose is connected, but
water fills up in the bucket.
ES,AS, P2and EC
appear inthe display
The PUMP operation light blinks
on and off every second
Pump does not empty bucket
the chart below first yourself.
SOLUTION
* Make sure the dehumidifier plug ispushed
completely into the outlet.
* Check the house fuse/circuit breaker box.
, Dehumidifier has reached its preset level
or bucket is full.
* Water bucket is not inthe proper position.
* The 3 minute compressor safety delay has
not expired.
* Did not allow enough time to remove the
moisture.
* Make sure there are no curtains, blinds or
furniture blocking the front or back of the
dehumidifier.
The humidify control may not be set low enough.
* Check that all doors, windows and other
openings are securely closed.
Room temperature is too low, below 41°F (5°C).
* There is a kerosene heater or something giving
off water vapor in the room.
° The air filter is clogged.
* The unit is tilted instead of upright as it should be.
, The floor surface is not level.
* This is normal. The dehumidifier has an auto
defrost feature.
* Hose to connector or hose connection may be
loose.
* The unit is set up for the bucket to collect water,
but the back drain plug is removed as if set up
for continuous drain. Replace the drain plug.
* Check drain hose, tube, and internal connector for
blockage.
* These are error codes and protection code.
See CONTROL PANEL section.
Clean the pump filter.
Check that the pump hose is not kinked or blocked.
Empty the water bucket.
° Pump runs for 10minutesand may lower water level
inbucket by 1inch.Thisis normal. Water level in bucket
will appear to be between three-quarters full and full
during normal operation.
16