User Manual
 Page 16 
1.  Place unit on floor, a bench or a table. There is a left and right side filler panel; be 
sure to use the proper panel for each side. When installed, the flange for securing 
the panel in place to the window sill will be facing into the room.
A. Hold the side panel in one hand and gently pull back the center to free the open 
end. See Fig. 1.
B.  Slide the free and “
I” section of the panel directly into the cabinet as shown in Fig. 2A.
  Slide the panel down. Be sure to leave enough space to slip the top and bottom of 
the frame into the rails on the cabinet.
C. Once the panel has been installed on the side of the cabinet, make sure it sits 
securely inside the frame channel by making slight adjustments.
  Slide the top and bottom ends of the frame into the top and bottom rails of the 
cabinet. Fig. 3.
How To Install
NOTE
Top rail and side panels at each side are offset to provide the proper pitch to the 
rear of 5/16” (8mm). This is necessary for proper condensed water management and 
drainage. If you are not using the side panels for any reason, this pitch to the rear 
must be maintained.
NOTE
For safety reasons, all 
four (4) screws MUST 
be securely fastened.
Fig. 1
Fig. F
Fig. G
C: Align the hole in the top rail with those in the top of the unit as shown in Fig. F.
D: Secure the top rail to the unit with the 3/8” screws as shown in Fig. G.
Installation
Instructions
“I” section
Fig. 2
Fig. 2
“I” section
Top Rail
Bottom Rail
Fig. 3
3. INSTALL THE ACCORDION PANELS