Installation Guide
4
 WARNING
•  Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair 
requiring the assistance of other skilled personnel shall be carried out under the supervision of a person 
competent in the use of fl ammable refrigerants.
•  DO NOT modify the length of the power cord or use an extension cord to power the unit.
•  DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fi re or 
electrical shock.
•  Please follow the instruction carefully to handle, install, clean, and service the appliance to avoid any damage 
or hazard.
Flammable
Refrigerant R32 is used within appliance.
•  When maintaining or disposing of the appliance, the refrigerant (R32) shall be recovered properly and shall 
not discharge to air directly.
•  Compliance with national gas regulations shall be observed.
•  Keep ventilation openings clear of obstruction.
•  The appliance shall be stored so as to prevent mechanical damage from occurring.
•  A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to 
the room area as specifi ed for operation.
•  Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid 
certifi cate from an industry-accredited assessment authority, which authorizes their competence to handle 
refrigerants safely in accordance with an industry recognized assessment specifi cation.
Examples for such working procedures are:
• Breaking into the refrigerating circuit;
• Opening of sealed components;
• Opening of ventilated enclosures.
• No open fi re or device like switch which may generate spark/arcing shall be around the appliance to avoid 
causing ignition of the fl ammable refrigerant used. Please follow the instruction carefully to store or maintain 
the appliance to prevent mechanical damage from occurring.
•  Do not use means to accelerate the defrosting process or to clean, other than those recommended by the 
manufacturer.
•  The appliance shall be stored in a room without continuously operating ignition sources (for example: open 
fl ames, an operating gas appliance) and ignition sourcesor (for example: an operating electric heater) close 
to the appliance.
•  Do not pierce or burn.
•  Be aware that the refrigerants may not contain an odor.
Electronic Work
NOTE: The cographs are for
explanation purpose only. Your
machine may be slightly dierent.
The actual shape shall prevail.
WARNING: 
BEFORE PERFORMING ANY ELECTRICAL OR WIRING
WORK, TURN OFF THE MAIN POWER TO THE SYSTEM.
DISPLAY
MAIN
CONTROL
POWER
SUPPLY
CORD