Service manual

34
10.3 Key parts checking.
10.3.1. Compressor checking (Model:
C-6RVN93H0N).
Measure the resistance value of each winding by using the multi-meter.
10.3.2 Outdoor Fan Motor (Model: YDK53-6F).
Measure the resistance value of each winding by using the multi-meter.
10.3.3 Indoor Fan Motor (Model: RPG28D).
Measure the resistance value of each winding by using the multi-meter.
Position Resistance Value
Blue - Red
Blue - Black
Red - Blue
0.668
(25)
Position Resistance Value
Black - Red
87.8 (20)
Red -Yellow 141.5 (20)
Position Resistance Value
Black - Red
220±8% (20)
White - Black 330±8% (20)