Before using your air conditioner, please read this manual carefully and keep it for future reference. INVERTER SPLIT- TYPE ROOM AIR CONDITIONER R ead This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips.
CONTENTS SOCIABLE REMARK Sociable remark.................................................................................................................................2 SAFETY PRECAUTIONS Warning ............................................................................................................................................3 Caution .............................................................................................................................................
SOCIABLE REMARK When using this air conditioner in the European countries, the follow information must be followed: DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.
SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to property. Meanings of symbols used in this manual are as shown below. Never do this.
SAFETY PRECAUTIONS CAUTION ! ! When the air filter is to be removed, do not touch the metal parts of the unit. Do not clean the air conditioner with water. It may cause an injury. Water may enter the unit and degrade the insulation. It may cause an electric shock. An oxygen shortage may occur. When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not put a pet or house plant where it will be exposed to direct air flow. Do not use for special purposes.
OPERATING INSTRUCTIONS Parts names Indoor unit Indoor unit Air inlet 1 2 3 4 14 5 6 7 Air outlet 8 9 ( C) FAN HIGH MED LOW URE ERAT TEMP SET AUTO COOL DRY HEAT 10 11 TEMP 12 D SPEE FF FAN R ON ON/O E MOD TIME P R OFF SLEE TIME SWING O LOCK RESET LED AY DISPL TURB AIR TION DIREC Outdoor unit 13 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
OPERATING INSTRUCTIONS TIMER display Displayed during Timer operation. FAN SPEED display CLEAN AIR display(optional) Displayed when Ionizer or Plasma dust collector(depending on models) is activated. Displayed the selected fan speed: AUTO(nothing) and three fan speed levels: LOW( ), MED( ) and HIGH( ). TURBO operation display Operation Frequency display Displayed when select TURBO function on cooling operation or on heating operation. This display is separated into five zones.
OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, see the <> packed with the unit for details. Operating temperature Mode Temperature Cooling operation Heating operation Drying operation >17 C Room temperature 18 C ~ 50 C Outdoor temperature ( -15 C~ 50 C:For the models with low temperature cooling system) <30 C >10 C -15 C ~ 34 C 10 C ~ 50 C CAUTION: 1.
OPERATING INSTRUCTIONS Airflow direction control SET TEMPERATURE ( C) FAN HIGH MED LOW AUTO COOL DRY HEAT TEMP MODE ON/OFF FAN SPEED DIRECTION SLEEP /SWING TIMER ON CLEAN AIR TIMER OFF RESET LOCK SELF FOLLOW LED ME CLEAN DISPLAY TURBO Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using the remote controller. Adjust the vertical louver manually.
OPERATING INSTRUCTIONS How the air conditioner works AUTO operation When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. If the AUTO mode is uncomfortable, you can select desired conditions manually.
CARE AND MAINTENANCE Care and maintenance Cleaning the Grille, Case and Remote Controller Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. Household Drain Cleaner No NOTE: Supply power must be disconnectd before cleaning the indoor unit. CAUTIONS Thinner A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit.
CARE AND MAINTENANCE 4. Remove the Air Freshening Filter(Optional filter: Plasma Dust Collector/Silver Ion filter /Bio filter / Vitamin C filter/3M air purifier filter) from its support frame. (The installation and removing method of the air freshening filter is different depending on the models,see the pictures marked 1 and 2 on the left. Clean the air freshening filter at least once a month, and replace it every 4-5 months. Clean it with vacuum cleaner, then dry it in cool place.
OPERATION TIPS The following events may occur during normal operation. 1. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. A) When heating has just starting. B) Defrosting. C) Low temperature heating.
OPERATION TIPS 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed. 8. Heating mode (For cooling and heating models only) The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation.
TROUBLESHOOTING TIPS Troubleshooting Tips Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center. OPERATION indicator or other indicators flash rapidly (5 times every second) and this flash can't be fixed by disconnecting the power, and then connect it in again. Trouble Fuse blows frequently or circuit breaker trips frequently. Other objects or water penetrate the air conditioner.
CS436-U