Manual
Table Of Contents
- Overview
- Chapter 1: Introduction
- Chapter 2: PRO Series Live Audio Systems
- Chapter 3: About The Control Centre
- Getting Started
- Chapter 4: Setting Up The System
- Basic Operation Of The PRO Series
- Chapter 5: Before You Start
- Chapter 6: Working With The Control Centre
- Chapter 7: Navigation
- Chapter 8: Patching
- Chapter 9: Basic Operation
- Setting a mic amplifier’s input gain
- Setting the high and low pass filters
- Input equalisation (E zone)
- Input dynamics processing (D zone)
- Output processing
- Using VCA/POP groups
- Setting up a mix
- Using fader flip
- Setting up the effects rack
- Simple routing to master stereo outputs
- Scene and show management (automation)
- Configuring the inputs and outputs
- Using copy and paste
- User library (presets)
- Surround panning
- Two-man operation
- Saving your show files to a USB memory stick
- Security (locking mode)
- Security (locking mode)
- Advanced Operation And Features
- Chapter 10: Stereo Linking
- Chapter 11: Panning
- Chapter 12: Soloing
- Chapter 13: Muting
- Chapter 14: Monitors And Communications
- Chapter 15: Graphic Equaliser (GEQ)
- Chapter 16: Internal Effects
- Overview of the internal effects
- About the effect window
- Working with the effects
- Effect configuration
- Effect programs
- Delay effect
- Virtual DN780 Reverb effect
- Flanger effect
- Phaser effect
- Pitch Shifter effect
- SQ1 Dynamics effect
- 3-Band Compressor effect
- Submonster
- DN60 Spectrum Analyser
- Tape Saturation
- Variable Phase
- Dual Stereo Delay
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Stereo Graphic EQ
- Dynamic EQ
- Matrix Mixer
- Stereo Chorus
- UNCL.D
- Loudspeaker Processor
- De-esser
- TC M350
- MIDAS Spectrum Analyser
- MIDAS Automixer
- Chapter 17: Control Groups
- Chapter 18: Copy And Paste
- Chapter 19: Assignable Controls (I Zone)
- Chapter 20: Scenes And Shows (Automation)
- About automation
- Automation controls
- Automation screen
- Using the right-click menu
- Scene contents
- Point scenes
- Numbering and navigation
- Global scene
- Initial snapshot scene (safe scene)
- Date and time
- Scene cue list
- Editing scene properties
- Adding a new scene
- Copying and deleting scenes
- Changing the order of the scenes
- Overriding store scope
- Using patching in automation
- Using zoom
- Show files
- Rehearsals
- Safes
- Chapter 21: Scope (Automation)
- Chapter 22: Events (Automation)
- Chapter 23: Crossfades (Automation)
- Chapter 24: User Libraries (Presets)
- Chapter 25: File Management
- Chapter 26: Using Other Devices With The PRO X
- Chapter 27: Changing The User Settings
- Setting the meter preferences
- Configuring a virtual soundcheck
- Restoring the PRO X defaults
- Checking the PRO X build information
- Setting the configuration preferences
- Changing the user interface preferences
- Configuring the channels, groups and internal units
- Changing the default input/output names
- Adjusting PRO X illumination
- Setting the time and date
- Chapter 28: Delay Compensation (Latency)
- Description
- Chapter 29: Panel Connections
- Chapter 30: Inputs
- Mic amp input gain (preliminary input processing)
- Chapter 31: Outputs
- Chapter 32: GUI Menu
- Appendices
- Appendix A: Application Notes
- Appendix B: Technical Specification
- Appendix C: KLARK TEKNIK DN370 GEQ
- Appendix D: KLARK TEKNIK DN780 Reverb
- Technical Specifications
- Appendix E: I/O Modules
- DL443 analogue Jack I/O module
- Appendix F: Replacing A Module
- Appendix G: Troubleshooting
- Appendix H: Updating PRO X Host Software
- Appendix I: Documentation
- Appendix K: Parameters Affected By Scope
- Appendix L: Parameters Affected By Automate Patching
- Appendix M: Parameters Protected By Safes
- Appendix N: Parameters Affected By Copy And Paste
- Appendix O: Parameters Affected By Stereo Linking
- Appendix P: Parameters Copied Through Scenes
- Appendix Q: Service Information
89 PRO X User Manual
Signal generator
The signal generator section can output to pink noise (pink noise generator) or sine wave tone (sinusoidal oscillator), and connect to the internal and external talk buses.
Signal generator controls on the control surface and GUI
Item Element Description
1 frequency/[freq] control knob Gives continuous adjustment of the sinusoidal oscillator frequency from 50 Hz to 5 kHz.
2 1 kHz/[1K] switch Overrides the swept frequency control (item 1) and provides a xed 1 kHz tone.
3 PINK switch Overrides the sinusoidal oscillator and converts output signal to pink noise.
4 OSC switch This OSC external switch connects signal generator output to talk external output XLR.
5 OSC switch
This OSC internal switch connects signal generator output to the control centre’s internal talk and talk
select buses. The internal talk bus can then be mixed onto any of the control centre’s buses by pressing
the internal talk switches associated with those buses, or mixed onto a group of buses by activating an
internal talk group (see “Talk osc/routing”).
6 level control knob Gives continuous adjustment of signal generator peak output signals from o (4) to +10 dB.
The OSC switches (internal and external) are the talk routing switches.
1
2
345
6
1
45
2
6
3