Manual

Table Of Contents
406 PRO X User Manual
Gates
Not applicable.
EQs
The following diagram shows the EQ parameters copied through scenes.
Item Control Parameter
1 EQ switch EQ on/o
2 gain control knob EQ gain level
3 width control knob EQ width
4 freq control knob EQ frequency
5 SHAPE switch Band 1 shelving mode: bell, warm, high pass 6 dB or high pass 12 dB
6 SHAPE switch Band 2 shelving mode: bell or high pass 24 dB
7* SHAPE switch Band 6 shelving mode: bell, soft, low pass 6 dB or low pass 12 dB
8 C/O switch Order of processing: Dyn.Ins.EQ or EQIns.Dyn.
*Not shown in diagram.
Note: Although band 6 is not shown above, the items in the table also apply. Theband has items 2, 3 and 4, and also includes item 7.
2
4
1
EQ processing
area in GUI
channel strip
1
3
2
5/6/7
4
3
2
4
3
2
6
3
2
3
4
4
5
aux send
overview in GUI
channel strip
4
8
8
Insert and conguration
processing area in GUI
channel strip