Manual
Table Of Contents
- Overview
- Chapter 1: Introduction
- Chapter 2: PRO Series Live Audio Systems
- Chapter 3: About The Control Centre
- Getting Started
- Chapter 4: Setting Up The System
- Basic Operation Of The PRO Series
- Chapter 5: Before You Start
- Chapter 6: Working With The Control Centre
- Chapter 7: Navigation
- Chapter 8: Patching
- Chapter 9: Basic Operation
- Setting a mic amplifier’s input gain
- Setting the high and low pass filters
- Input equalisation (E zone)
- Input dynamics processing (D zone)
- Output processing
- Using VCA/POP groups
- Setting up a mix
- Using fader flip
- Setting up the effects rack
- Simple routing to master stereo outputs
- Scene and show management (automation)
- Configuring the inputs and outputs
- Using copy and paste
- User library (presets)
- Surround panning
- Two-man operation
- Saving your show files to a USB memory stick
- Security (locking mode)
- Security (locking mode)
- Advanced Operation And Features
- Chapter 10: Stereo Linking
- Chapter 11: Panning
- Chapter 12: Soloing
- Chapter 13: Muting
- Chapter 14: Monitors And Communications
- Chapter 15: Graphic Equaliser (GEQ)
- Chapter 16: Internal Effects
- Overview of the internal effects
- About the effect window
- Working with the effects
- Effect configuration
- Effect programs
- Delay effect
- Virtual DN780 Reverb effect
- Flanger effect
- Phaser effect
- Pitch Shifter effect
- SQ1 Dynamics effect
- 3-Band Compressor effect
- Submonster
- DN60 Spectrum Analyser
- Tape Saturation
- Variable Phase
- Dual Stereo Delay
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Stereo Graphic EQ
- Dynamic EQ
- Matrix Mixer
- Stereo Chorus
- UNCL.D
- Loudspeaker Processor
- De-esser
- TC M350
- MIDAS Spectrum Analyser
- MIDAS Automixer
- Chapter 17: Control Groups
- Chapter 18: Copy And Paste
- Chapter 19: Assignable Controls (I Zone)
- Chapter 20: Scenes And Shows (Automation)
- About automation
- Automation controls
- Automation screen
- Using the right-click menu
- Scene contents
- Point scenes
- Numbering and navigation
- Global scene
- Initial snapshot scene (safe scene)
- Date and time
- Scene cue list
- Editing scene properties
- Adding a new scene
- Copying and deleting scenes
- Changing the order of the scenes
- Overriding store scope
- Using patching in automation
- Using zoom
- Show files
- Rehearsals
- Safes
- Chapter 21: Scope (Automation)
- Chapter 22: Events (Automation)
- Chapter 23: Crossfades (Automation)
- Chapter 24: User Libraries (Presets)
- Chapter 25: File Management
- Chapter 26: Using Other Devices With The PRO X
- Chapter 27: Changing The User Settings
- Setting the meter preferences
- Configuring a virtual soundcheck
- Restoring the PRO X defaults
- Checking the PRO X build information
- Setting the configuration preferences
- Changing the user interface preferences
- Configuring the channels, groups and internal units
- Changing the default input/output names
- Adjusting PRO X illumination
- Setting the time and date
- Chapter 28: Delay Compensation (Latency)
- Description
- Chapter 29: Panel Connections
- Chapter 30: Inputs
- Mic amp input gain (preliminary input processing)
- Chapter 31: Outputs
- Chapter 32: GUI Menu
- Appendices
- Appendix A: Application Notes
- Appendix B: Technical Specification
- Appendix C: KLARK TEKNIK DN370 GEQ
- Appendix D: KLARK TEKNIK DN780 Reverb
- Technical Specifications
- Appendix E: I/O Modules
- DL443 analogue Jack I/O module
- Appendix F: Replacing A Module
- Appendix G: Troubleshooting
- Appendix H: Updating PRO X Host Software
- Appendix I: Documentation
- Appendix K: Parameters Affected By Scope
- Appendix L: Parameters Affected By Automate Patching
- Appendix M: Parameters Protected By Safes
- Appendix N: Parameters Affected By Copy And Paste
- Appendix O: Parameters Affected By Stereo Linking
- Appendix P: Parameters Copied Through Scenes
- Appendix Q: Service Information
198 PRO X User Manual
Navigating the PEQ output bands
You can change band selection by clicking the UP/DOWN buttons in the EQ
processing area. This will change selection by one band at a time.
EQ graph
The controls in the output EQ sections, that is, the EQ gain, freq and width
control knobs, have a similar functionality to the ones in the input EQ sections.
For details, see “EQ graph” in chapter 30.
Mute, safes, level and solo
Each output fast strip (control surface and GUI) has controls for muting, soloing,
safes and output signal level control. This is supported on the GUI in the
appropriate processing area. In addition, the channel strips (control surface and
GUI) have the full complement of safes.
Yellow rectangle
shows which four
bands are currently
displayed. Bands are
shown in descending
order from top to
bottom (Band 6 is
top).
Band navigation
buttons
Red (Band 1)
Blue (Band 5)
Green (Band 4)
Yellow (Band 3)
Orange (Band 2)
Magenta (Band 6)
Mute, safes, level and solo areas for the output channels on the control surface and GUI
GUI channel strip
Mute, solo and fader
processing area
GUI output fast strip
1
9
4
8
10
11
12
13
1
4
8
5
2
67
567