Manual
Table Of Contents
- Overview
- Chapter 1: Introduction
- Chapter 2: PRO Series Live Audio Systems
- Chapter 3: About The Control Centre
- Getting Started
- Chapter 4: Setting Up The System
- Basic Operation Of The PRO Series
- Chapter 5: Before You Start
- Chapter 6: Working With The Control Centre
- Chapter 7: Navigation
- Chapter 8: Patching
- Chapter 9: Basic Operation
- Setting a mic amplifier’s input gain
- Setting the high and low pass filters
- Input equalisation (E zone)
- Input dynamics processing (D zone)
- Output processing
- Using VCA/POP groups
- Setting up a mix
- Using fader flip
- Setting up the effects rack
- Simple routing to master stereo outputs
- Scene and show management (automation)
- Configuring the inputs and outputs
- Using copy and paste
- User library (presets)
- Surround panning
- Two-man operation
- Saving your show files to a USB memory stick
- Security (locking mode)
- Security (locking mode)
- Advanced Operation And Features
- Chapter 10: Stereo Linking
- Chapter 11: Panning
- Chapter 12: Soloing
- Chapter 13: Muting
- Chapter 14: Monitors And Communications
- Chapter 15: Graphic Equaliser (GEQ)
- Chapter 16: Internal Effects
- Overview of the internal effects
- About the effect window
- Working with the effects
- Effect configuration
- Effect programs
- Delay effect
- Virtual DN780 Reverb effect
- Flanger effect
- Phaser effect
- Pitch Shifter effect
- SQ1 Dynamics effect
- 3-Band Compressor effect
- Submonster
- DN60 Spectrum Analyser
- Tape Saturation
- Variable Phase
- Dual Stereo Delay
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Stereo Graphic EQ
- Dynamic EQ
- Matrix Mixer
- Stereo Chorus
- UNCL.D
- Loudspeaker Processor
- De-esser
- TC M350
- MIDAS Spectrum Analyser
- MIDAS Automixer
- Chapter 17: Control Groups
- Chapter 18: Copy And Paste
- Chapter 19: Assignable Controls (I Zone)
- Chapter 20: Scenes And Shows (Automation)
- About automation
- Automation controls
- Automation screen
- Using the right-click menu
- Scene contents
- Point scenes
- Numbering and navigation
- Global scene
- Initial snapshot scene (safe scene)
- Date and time
- Scene cue list
- Editing scene properties
- Adding a new scene
- Copying and deleting scenes
- Changing the order of the scenes
- Overriding store scope
- Using patching in automation
- Using zoom
- Show files
- Rehearsals
- Safes
- Chapter 21: Scope (Automation)
- Chapter 22: Events (Automation)
- Chapter 23: Crossfades (Automation)
- Chapter 24: User Libraries (Presets)
- Chapter 25: File Management
- Chapter 26: Using Other Devices With The PRO X
- Chapter 27: Changing The User Settings
- Setting the meter preferences
- Configuring a virtual soundcheck
- Restoring the PRO X defaults
- Checking the PRO X build information
- Setting the configuration preferences
- Changing the user interface preferences
- Configuring the channels, groups and internal units
- Changing the default input/output names
- Adjusting PRO X illumination
- Setting the time and date
- Chapter 28: Delay Compensation (Latency)
- Description
- Chapter 29: Panel Connections
- Chapter 30: Inputs
- Mic amp input gain (preliminary input processing)
- Chapter 31: Outputs
- Chapter 32: GUI Menu
- Appendices
- Appendix A: Application Notes
- Appendix B: Technical Specification
- Appendix C: KLARK TEKNIK DN370 GEQ
- Appendix D: KLARK TEKNIK DN780 Reverb
- Technical Specifications
- Appendix E: I/O Modules
- DL443 analogue Jack I/O module
- Appendix F: Replacing A Module
- Appendix G: Troubleshooting
- Appendix H: Updating PRO X Host Software
- Appendix I: Documentation
- Appendix K: Parameters Affected By Scope
- Appendix L: Parameters Affected By Automate Patching
- Appendix M: Parameters Protected By Safes
- Appendix N: Parameters Affected By Copy And Paste
- Appendix O: Parameters Affected By Stereo Linking
- Appendix P: Parameters Copied Through Scenes
- Appendix Q: Service Information
196 PRO X User Manual
Item Control Function
7
ratio/range/
[ratio] control
knob
This compressor control adjusts the amount of compression applied to signals above threshold.
Range is from innity (∞) to 1:1. When set to maximum (1:1), sets compressor to limiter mode.
8
attack control
knob
This compressor control adjusts the time it takes the compressor to respond after an over-threshold signal. Range is from
0.2ms to 20ms (milliseconds).
9 MODE switch
Selects compressor mode from the ve compressor types available (see “PRO Series compressor modes (dynamic)” in
Appendix A).
10
release control
knob
This compressor control adjusts the time it takes the compressor to recover after programme material falls back below
threshold. Range is from 0.05s to 3.00s (seconds).
11 Meter Compressor ‘gain reduction’ meter.
EQ (E zone)
For tonal control of the aux, matrix and master output signals, the output
channel EQ has the option of a six-band sweep parametric EQ (PEQ) or an
assignable graphic EQ (GEQ).
PEQ
The parametric EQ section (E zone) of the channel strip (mix and master bays)
allows tonal control of the input signal. The E zone contains all of the PEQ
controls, along with a shelving mode selection button and another set of band
selection buttons.
All of the outputs, except returns, have six-band PEQs. Two of the six bands have
three shelving modes each, while another has just one. Any combination of
the six bands can be used to control the signal, although only one band can be
adjusted in the E zone at any time. However, the EQ processing area (GUI channel
strip) displays four bands at any time, and also has navigational controls.
The returns have a four-band PEQ, which is similar to that used on the inputs.
For information, see “EQ (E zone)” in chapter 30.
PEQ sections for the output channels on the control surface and GUI