Input metering
Change to “The Console Overview screen shows all of the meters all of the time.
Meters can be switched globally to monitor the raw A/D input point, and are also individually switchable using the CHECK button in the gain trim section
(see “Mic amp input gain (preliminary input processing)”).
Input metering on the control surface and master bay GUI screen
4
2
3
1
5
6
Item Element Description
1 signal level meter
20-segment LED meter ‘cluster’. Defaults to monitor pre-fader signal level. Meter range is +21 dB to
-36 dB, in 3 dB increments.
2
gain reduction
meter
Seven-segment LED meter monitors the amount of gain reduction when using a compressor.
Meter range is 1dB to 20 dB, in varying increments.
3 gate meter
Seven-segment LED meter, monitors the amount of gain reduction when using a gate.
Meter range is 5 dB to 35 dB, in 5 dB increments.
4 PRE switch Global meter switch that switches all inputs to monitor the raw A/D input point
5 Input channel area Shows the meters for all of the input channels.
6 Clr. Peaks button This button momentarily clears the meter peaks.