Manual
Table Of Contents
- Overview
- Chapter 1: Introduction
- Chapter 2: PRO Series Live Audio Systems
- Chapter 3: About The Control Centre
- Getting Started
- Chapter 4: Setting Up The System
- Basic Operation Of The PRO Series
- Chapter 5: Before You Start
- Chapter 6: Working With The Control Centre
- Chapter 7: Navigation
- Chapter 8: Patching
- Chapter 9: Basic Operation
- Setting a mic amplifier’s input gain
- Setting the high and low pass filters
- Input equalisation (E zone)
- Input dynamics processing (D zone)
- Output processing
- Using VCA/POP groups
- Setting up a mix
- Using fader flip
- Setting up the effects rack
- Simple routing to master stereo outputs
- Scene and show management (automation)
- Configuring the inputs and outputs
- Using copy and paste
- User library (presets)
- Surround panning
- Two-man operation
- Saving your show files to a USB memory stick
- Security (locking mode)
- Security (locking mode)
- Advanced Operation And Features
- Chapter 10: Stereo Linking
- Chapter 11: Panning
- Chapter 12: Soloing
- Chapter 13: Muting
- Chapter 14: Monitors And Communications
- Chapter 15: Graphic Equaliser (GEQ)
- Chapter 16: Internal Effects
- Overview of the internal effects
- About the effect window
- Working with the effects
- Effect configuration
- Effect programs
- Delay effect
- Virtual DN780 Reverb effect
- Flanger effect
- Phaser effect
- Pitch Shifter effect
- SQ1 Dynamics effect
- 3-Band Compressor effect
- Submonster
- DN60 Spectrum Analyser
- Tape Saturation
- Variable Phase
- Dual Stereo Delay
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Stereo Graphic EQ
- Dynamic EQ
- Matrix Mixer
- Stereo Chorus
- UNCL.D
- Loudspeaker Processor
- De-esser
- TC M350
- MIDAS Spectrum Analyser
- MIDAS Automixer
- Chapter 17: Control Groups
- Chapter 18: Copy And Paste
- Chapter 19: Assignable Controls (I Zone)
- Chapter 20: Scenes And Shows (Automation)
- About automation
- Automation controls
- Automation screen
- Using the right-click menu
- Scene contents
- Point scenes
- Numbering and navigation
- Global scene
- Initial snapshot scene (safe scene)
- Date and time
- Scene cue list
- Editing scene properties
- Adding a new scene
- Copying and deleting scenes
- Changing the order of the scenes
- Overriding store scope
- Using patching in automation
- Using zoom
- Show files
- Rehearsals
- Safes
- Chapter 21: Scope (Automation)
- Chapter 22: Events (Automation)
- Chapter 23: Crossfades (Automation)
- Chapter 24: User Libraries (Presets)
- Chapter 25: File Management
- Chapter 26: Using Other Devices With The PRO X
- Chapter 27: Changing The User Settings
- Setting the meter preferences
- Configuring a virtual soundcheck
- Restoring the PRO X defaults
- Checking the PRO X build information
- Setting the configuration preferences
- Changing the user interface preferences
- Configuring the channels, groups and internal units
- Changing the default input/output names
- Adjusting PRO X illumination
- Setting the time and date
- Chapter 28: Delay Compensation (Latency)
- Description
- Chapter 29: Panel Connections
- Chapter 30: Inputs
- Mic amp input gain (preliminary input processing)
- Chapter 31: Outputs
- Chapter 32: GUI Menu
- Appendices
- Appendix A: Application Notes
- Appendix B: Technical Specification
- Appendix C: KLARK TEKNIK DN370 GEQ
- Appendix D: KLARK TEKNIK DN780 Reverb
- Technical Specifications
- Appendix E: I/O Modules
- DL443 analogue Jack I/O module
- Appendix F: Replacing A Module
- Appendix G: Troubleshooting
- Appendix H: Updating PRO X Host Software
- Appendix I: Documentation
- Appendix K: Parameters Affected By Scope
- Appendix L: Parameters Affected By Automate Patching
- Appendix M: Parameters Protected By Safes
- Appendix N: Parameters Affected By Copy And Paste
- Appendix O: Parameters Affected By Stereo Linking
- Appendix P: Parameters Copied Through Scenes
- Appendix Q: Service Information
142 PRO X User Manual
>> To open the Files screen
To open the Files screen, do one of the following:
• At a GUI screen, choose home Files.
• In the primary navigation zone, press the automation/ling screen access
button twice.
About the Master Controller File
Synchronisation window
The Master Controller File Synchronisation window manages the
synchronisation between the two master controllers.
1 2 3 4
5
6
7891011
2
7
Master Controller File Synchronisation window
Item Element Description
1
master controller 1 status
eld
Shows whether this master controller is active or on standby.
2 MAKE ACTIVE button Activates the respective master controller.
3
master controller 2
status eld
Shows whether this master controller is active or on standby.
4 status eld Shows whether the master controllers are synchronised (green text) or not (red text).
5 Lists of master controller les
Lists the les loaded on each master controller and indicates whether they are synchronised (blue text)
or not (red text).
6 COPY ALL TO MC1 button Copies all les listed in the master controller 2 panel to master controller 1.
7 DELETE button Deletes the selected le in its respective panel.
8 COPY TO MC1 button Copies selected le in the master controller 2 panel to master controller 1.
9 CLOSE button Closes this window.
10 COPY ALL TO MC2 button Copies all les listed in the master controller 1 panel to master controller 2.
11 COPY TO MC2 button Copies selected le in the master controller 1 panel to master controller 2.