Manual
Table Of Contents
- Overview
- Chapter 1: Introduction
- Chapter 2: PRO Series Live Audio Systems
- Chapter 3: About The Control Centre
- Getting Started
- Chapter 4: Setting Up The System
- Basic Operation Of The PRO Series
- Chapter 5: Before You Start
- Chapter 6: Working With The Control Centre
- Chapter 7: Navigation
- Chapter 8: Patching
- Chapter 9: Basic Operation
- Setting a mic amplifier’s input gain
- Setting the high and low pass filters
- Input equalisation (E zone)
- Input dynamics processing (D zone)
- Output processing
- Using VCA/POP groups
- Setting up a mix
- Using fader flip
- Setting up the effects rack
- Simple routing to master stereo outputs
- Scene and show management (automation)
- Configuring the inputs and outputs
- Using copy and paste
- User library (presets)
- Surround panning
- Two-man operation
- Saving your show files to a USB memory stick
- Security (locking mode)
- Security (locking mode)
- Advanced Operation And Features
- Chapter 10: Stereo Linking
- Chapter 11: Panning
- Chapter 12: Soloing
- Chapter 13: Muting
- Chapter 14: Monitors And Communications
- Chapter 15: Graphic Equaliser (GEQ)
- Chapter 16: Internal Effects
- Overview of the internal effects
- About the effect window
- Working with the effects
- Effect configuration
- Effect programs
- Delay effect
- Virtual DN780 Reverb effect
- Flanger effect
- Phaser effect
- Pitch Shifter effect
- SQ1 Dynamics effect
- 3-Band Compressor effect
- Submonster
- DN60 Spectrum Analyser
- Tape Saturation
- Variable Phase
- Dual Stereo Delay
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Stereo Graphic EQ
- Dynamic EQ
- Matrix Mixer
- Stereo Chorus
- UNCL.D
- Loudspeaker Processor
- De-esser
- TC M350
- MIDAS Spectrum Analyser
- MIDAS Automixer
- Chapter 17: Control Groups
- Chapter 18: Copy And Paste
- Chapter 19: Assignable Controls (I Zone)
- Chapter 20: Scenes And Shows (Automation)
- About automation
- Automation controls
- Automation screen
- Using the right-click menu
- Scene contents
- Point scenes
- Numbering and navigation
- Global scene
- Initial snapshot scene (safe scene)
- Date and time
- Scene cue list
- Editing scene properties
- Adding a new scene
- Copying and deleting scenes
- Changing the order of the scenes
- Overriding store scope
- Using patching in automation
- Using zoom
- Show files
- Rehearsals
- Safes
- Chapter 21: Scope (Automation)
- Chapter 22: Events (Automation)
- Chapter 23: Crossfades (Automation)
- Chapter 24: User Libraries (Presets)
- Chapter 25: File Management
- Chapter 26: Using Other Devices With The PRO X
- Chapter 27: Changing The User Settings
- Setting the meter preferences
- Configuring a virtual soundcheck
- Restoring the PRO X defaults
- Checking the PRO X build information
- Setting the configuration preferences
- Changing the user interface preferences
- Configuring the channels, groups and internal units
- Changing the default input/output names
- Adjusting PRO X illumination
- Setting the time and date
- Chapter 28: Delay Compensation (Latency)
- Description
- Chapter 29: Panel Connections
- Chapter 30: Inputs
- Mic amp input gain (preliminary input processing)
- Chapter 31: Outputs
- Chapter 32: GUI Menu
- Appendices
- Appendix A: Application Notes
- Appendix B: Technical Specification
- Appendix C: KLARK TEKNIK DN370 GEQ
- Appendix D: KLARK TEKNIK DN780 Reverb
- Technical Specifications
- Appendix E: I/O Modules
- DL443 analogue Jack I/O module
- Appendix F: Replacing A Module
- Appendix G: Troubleshooting
- Appendix H: Updating PRO X Host Software
- Appendix I: Documentation
- Appendix K: Parameters Affected By Scope
- Appendix L: Parameters Affected By Automate Patching
- Appendix M: Parameters Protected By Safes
- Appendix N: Parameters Affected By Copy And Paste
- Appendix O: Parameters Affected By Stereo Linking
- Appendix P: Parameters Copied Through Scenes
- Appendix Q: Service Information
108 PRO X User Manual
Chapter 17: Control Groups
PRO X control groups comprise VCA/POP groups, auto-mute groups and talk
groups. This chapter explains the function of each group and shows you the areas
on the control surface and GUI that are used for their operation and management.
Many of the control group functions can be operated at either the control surface
or GUI. Each control group has its own area on the control surface from where
its groups can be set up and recalled, and there is a main option in the GUI menu
(Control Groups) from which you can open the Groups Sheet screen and the
group-specic screens. Using these screens, you can congure and operate the
groups, and also manage group membership.
VCA and POP groups
Using the VCA/POP group controls, you can bring selected channels to the control
surface for joint control. The VCA/POP group sections are situated at the bottom
of the mix bay. When a VCA/POP is selected, its members are unfolded to the
input bays.
There are 10 VCA groups. Their controls, such as fader, LCD select button etc.,
are housed in fast strips at the bottom of the mix bay. POP groups, however, are
fewer in number (eight-o). These only have an LCD each, and are housed in a
population groups section just above the VCAs.
The GUI provides full support for the hardware controls. This is in the
VCA Groups screen of the GUI menu, which also includes an unfold button and
a solo area B button for each group. This screen also provides VCA/POP group
conguration and management functions.
Each VCA/POP group can have a combination of channel types as members,
although it is usual to have only either inputs or outputs. Only the input channels
are unfolded to the control surface (in the input bays).
>> To open the VCA Groups screen
At the GUI, choose home Control Groups VCA Groups.
VCA and POP groups on the control surface and GUI
POP groups
VCA groups
POP groups
VCA groups