Manual
Table Of Contents
- HD96-24 Overview
- Chapter 1. Introduction
- Chapter 2. HD96-24 Overview
- Chapter 3. System Setup
- Initial set-up procedure
- Unpacking the equipment
- Ventilation
- Racking the I/O
- Connection instructions
- System components
- Powering the system
- Switching on the HD96-24
- To switch off the HD96-24 surface
- Setting up the ID of the unit(s)
- To set up the ID of a I/O unit
- I/O Box Update
- Connection to the internet
- Hardware Connections
- Chapter 4. Before You Start
- Chapter 5. About the Control Surface
- Chapter 6. Navigation
- Navigating via the surface detail area
- Navigating via the GUI Menu Bar
- Side Bar Menu
- Widgets and Rotary Controls
- Workflow Modes Overview
- Overview
- Side Bar Pop Op Display
- Tags and Pops
- Clipping Channels
- Bus Setup and Outputs Management
- Meter Bridge
- Channel View
- Console View
- FOH View
- Automation View
- Navigating via Touch Screen Faders
- Navigating via the Layer Overview/Channel Strips area
- Navigation via Global Assignable Shortcuts area
- Navigation via Pinned Fader and Assignable Controls
- Flip Mode
- One Shot Pot
- Clipped Channels, fault finding a problem channel
- Console Layout Configuration (Navigation)
- Creating a Custom Layout
- Chapter 7. Patching
- Chapter 8. Basic Operation
- Scene and show management (Automation)
- Clear the Console
- Saving and Loading show files to a USB memory stick
- Saving and Loading show files to the mCloud
- Save & Mark
- Rollback
- Load Options
- Automate patching preferences:
- Naming Page
- Channel Tags
- Channel Configuration (Config)
- Setting a Pre-Amp’s input gain
- Linking & Stereo
- Patching
- Direct Output
- Options
- Configuration Pages for Outputs
- Linking & Stereo (Outputs)
- Patching (Outputs)
- Direct Input
- Options
- Oscillator (Output Widget)
- Setting the HPF and LPF
- Input equalisation
- True Audition
- Output processing
- Input Dynamics Processing (Dynamics Section)
- Using VCA & POP groups
- How to configure a VCA/POP group:
- Alternative way to assign VCA/POP groups
- Routing to master stereo outputs
- Manchino Multi Edit Page (Basic introduction)
- Security (locking mode)
- Chapter 9. Stereo Linking
- Chapter 10. Panning
- Chapter 11. Soloing
- Chapter 12. Chapter 12: Muting
- Chapter 13. Monitors and Shout Configuration
- Chapter 14. Graphic EQ (GEQ)
- Chapter 15. Internal Effects
- Effects overview
- Working with channel inserted effects
- Effects Browser
- Effect Rack
- Effect Sub-slots
- Effects Rack Safes
- FX Mode
- Effect Programs
- Reverbs:
- TC Electronic VSS4 Reverb
- TC Electronic VSS3 Reverb
- TC M350
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Delays:
- Midas Delay
- Stereo Delay
- TC 2290 Delay
- KT 1176 Limiting Amplifier
- KT Bus Compressor
- R-Comp
- Smart Dynamics Processor
- Dual De-Esser
- DSR De-esser
- PIE (Prime Input Expander)
- Stressor Compressor
- Dual Band & Brickwall limiter.
- Midas U Flange
- Midas U Phase
- Pitch Shifter
- Chorus
- Rotor Motor
- Distortion/Exciter:
- Enlightenment Bass
- Glow
- Tape Saturation
- UNCL.HD MULTIBAND DISTORTION
- M Harmonics
- Chapter 16. Talk and Mute Groups
- Talk Groups
- Mute groups
- Using copy and paste
- Copy and Paste rules and restrictions
- Channels Versus Scenes
- Copy and Paste Parameters
- About the Assignable Rotary
- Controlling the Assignable rotary controls
- Pinned Channels
- Flip Target
- Global Assignable Shortcuts
- Assignables Types: Automation
- Assignables Types: Groups.
- Chapter 19. Automation (Scenes and Shows)
- Chapter 20. Show Editor (Recall and Store Scope)
- Chapter 21. Events (Automation)
- Chapter 22. Crossfade Events
- Chapter 23. TBC
- Chapter 24. File Management
- Chapter 25. Multiple Consoles and Other Devices
- Chapter 26. Preferences (Console Configuration)
- Chapter 27. Delay Compensation (Latency)
- Chapter 28. Panel Connections
- Chapter 29. Inputs
- Input channel routing
- Input channel areas of the control surface
- Input Widget Area
- The following processing sections are available:
- Channel View Workflow
- Side Bar Area
- Channel View
- Sends Overview
- Send Detail Area
- Input channel delay
- Aux return mode
- Effects Insert
- Input Metering
- Input Inserts
- Options - Processing Order
- Safes
- Mic Amp Input Gain
- Dynamics and mode descriptions
- Compressor
- Compressor modes
- Corrective mode (exponential peak - fast)
- Adaptive mode (exponential RMS - accurate)
- Creative mode (linear peak - slow)
- Vintage mode (adaptive peak - bright)
- Compressor Graph
- Ratio
- Knee
- Gate
- Ducker
- Sidechain
- EQ
- Phase (All Pass Filter) Controls
- Mixes
- Input channel Pick Off points
- Masters Section and Pan Control
- LCD Displays
- Chapter 30. Outputs
- Outputs on Channel Banks
- GUI channel strips
- Master Section on the control surface
- Output metering
- Bus trim (GUI only)
- Compressor (Dynamics)
- EQ (Equaliser)
- Mute, safes, level and solo
- Output channel name
- Output channel source/destination (GUI only)
- Stereo linking
- Output Configuration Patching
- Safes
- Insert
- Output channel delay
- Processing Order
- Mixes
- Masters
- Outputs macro interrogation control
- Flexi-Aux
- Chapter 31. GUI Menu (Side Bar Menu)
- Chapter 32. Configuring a virtual soundcheck
- Chapter 33. Manchino (Multi Edit Page)
- Chapter 34. Update Manager
- Chapter 35. Channel AI
- Chapter 36. Specifications
276 HD96-24-CC-TP User Manual
EQ (Equaliser)
For tonal control of the aux, matrix and master output signals, the output channel EQ has the option of a 4 band swept parametric EQ (PEQ).
The parametric EQ section of the channel allows tonal control of the input signal. The EQ contains all the PEQ controls, along with a shelving mode selection button and
another set of band selection buttons.
All the outputs, except returns, have 4-band PEQs. Two of the 4 bands have two lter modes plus a shelf option, while band 2 can be made into a 24 dB HPF lter, this
mode removes band one from use. Any combination of the four bands can be used to control the signal.
For more information, see “EQ” in Chapter 29.
Mute, safes, level and solo
Each output (control surface and GUI) has controls for muting, soloing, and output signal level control. This is supported on the GUI in the appropriate widget area. In
addition, the Conguration page in Automation workow, Home workow, FOH workow and Channel View page have access to the channel safes when needed to
stop certain parameters from being recalled on a scene change.
Output channel name
You can change the channel name in the GUI and surface LCD channel display. This can be done in the Channel View page or in any of the processing widgets by long
pressing- the channel name. Here you can change the background colour of the output channel name eld and/or the channel name. You can also open the manchino
page in the GUI menu or click the large channel icon in the side bar display to name channels.
Chapter 8 Basic Operations explains how to name all channels.
Output channel source/destination (GUI only)
The channel’s destination is shown in the conguration widget, patching page. If no destination has been selected, it will display no patch information. You can select
the destination for this channel by clicking the patch image, which opens the patching workow (see Chapter 7 “Patching”).
Stereo linking
The Linking & Stereo section of the Conguration page in widget has a Mono, Link or Stereo button for linking the selected output channel to the adjacent (higher
numbered) output channel. You can select the linked parameters and pan law settings.
On the surface in the CONFIG area you can link a selected mono channel by pressing the Link button. This links the selected mono channel to the next, if the next
channel is also mono.
For more information, see Chapter 9 “Stereo Linking”.