Manual
Table Of Contents
- HD96-24 Overview
- Chapter 1. Introduction
- Chapter 2. HD96-24 Overview
- Chapter 3. System Setup
- Initial set-up procedure
- Unpacking the equipment
- Ventilation
- Racking the I/O
- Connection instructions
- System components
- Powering the system
- Switching on the HD96-24
- To switch off the HD96-24 surface
- Setting up the ID of the unit(s)
- To set up the ID of a I/O unit
- I/O Box Update
- Connection to the internet
- Hardware Connections
- Chapter 4. Before You Start
- Chapter 5. About the Control Surface
- Chapter 6. Navigation
- Navigating via the surface detail area
- Navigating via the GUI Menu Bar
- Side Bar Menu
- Widgets and Rotary Controls
- Workflow Modes Overview
- Overview
- Side Bar Pop Op Display
- Tags and Pops
- Clipping Channels
- Bus Setup and Outputs Management
- Meter Bridge
- Channel View
- Console View
- FOH View
- Automation View
- Navigating via Touch Screen Faders
- Navigating via the Layer Overview/Channel Strips area
- Navigation via Global Assignable Shortcuts area
- Navigation via Pinned Fader and Assignable Controls
- Flip Mode
- One Shot Pot
- Clipped Channels, fault finding a problem channel
- Console Layout Configuration (Navigation)
- Creating a Custom Layout
- Chapter 7. Patching
- Chapter 8. Basic Operation
- Scene and show management (Automation)
- Clear the Console
- Saving and Loading show files to a USB memory stick
- Saving and Loading show files to the mCloud
- Save & Mark
- Rollback
- Load Options
- Automate patching preferences:
- Naming Page
- Channel Tags
- Channel Configuration (Config)
- Setting a Pre-Amp’s input gain
- Linking & Stereo
- Patching
- Direct Output
- Options
- Configuration Pages for Outputs
- Linking & Stereo (Outputs)
- Patching (Outputs)
- Direct Input
- Options
- Oscillator (Output Widget)
- Setting the HPF and LPF
- Input equalisation
- True Audition
- Output processing
- Input Dynamics Processing (Dynamics Section)
- Using VCA & POP groups
- How to configure a VCA/POP group:
- Alternative way to assign VCA/POP groups
- Routing to master stereo outputs
- Manchino Multi Edit Page (Basic introduction)
- Security (locking mode)
- Chapter 9. Stereo Linking
- Chapter 10. Panning
- Chapter 11. Soloing
- Chapter 12. Chapter 12: Muting
- Chapter 13. Monitors and Shout Configuration
- Chapter 14. Graphic EQ (GEQ)
- Chapter 15. Internal Effects
- Effects overview
- Working with channel inserted effects
- Effects Browser
- Effect Rack
- Effect Sub-slots
- Effects Rack Safes
- FX Mode
- Effect Programs
- Reverbs:
- TC Electronic VSS4 Reverb
- TC Electronic VSS3 Reverb
- TC M350
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Delays:
- Midas Delay
- Stereo Delay
- TC 2290 Delay
- KT 1176 Limiting Amplifier
- KT Bus Compressor
- R-Comp
- Smart Dynamics Processor
- Dual De-Esser
- DSR De-esser
- PIE (Prime Input Expander)
- Stressor Compressor
- Dual Band & Brickwall limiter.
- Midas U Flange
- Midas U Phase
- Pitch Shifter
- Chorus
- Rotor Motor
- Distortion/Exciter:
- Enlightenment Bass
- Glow
- Tape Saturation
- UNCL.HD MULTIBAND DISTORTION
- M Harmonics
- Chapter 16. Talk and Mute Groups
- Talk Groups
- Mute groups
- Using copy and paste
- Copy and Paste rules and restrictions
- Channels Versus Scenes
- Copy and Paste Parameters
- About the Assignable Rotary
- Controlling the Assignable rotary controls
- Pinned Channels
- Flip Target
- Global Assignable Shortcuts
- Assignables Types: Automation
- Assignables Types: Groups.
- Chapter 19. Automation (Scenes and Shows)
- Chapter 20. Show Editor (Recall and Store Scope)
- Chapter 21. Events (Automation)
- Chapter 22. Crossfade Events
- Chapter 23. TBC
- Chapter 24. File Management
- Chapter 25. Multiple Consoles and Other Devices
- Chapter 26. Preferences (Console Configuration)
- Chapter 27. Delay Compensation (Latency)
- Chapter 28. Panel Connections
- Chapter 29. Inputs
- Input channel routing
- Input channel areas of the control surface
- Input Widget Area
- The following processing sections are available:
- Channel View Workflow
- Side Bar Area
- Channel View
- Sends Overview
- Send Detail Area
- Input channel delay
- Aux return mode
- Effects Insert
- Input Metering
- Input Inserts
- Options - Processing Order
- Safes
- Mic Amp Input Gain
- Dynamics and mode descriptions
- Compressor
- Compressor modes
- Corrective mode (exponential peak - fast)
- Adaptive mode (exponential RMS - accurate)
- Creative mode (linear peak - slow)
- Vintage mode (adaptive peak - bright)
- Compressor Graph
- Ratio
- Knee
- Gate
- Ducker
- Sidechain
- EQ
- Phase (All Pass Filter) Controls
- Mixes
- Input channel Pick Off points
- Masters Section and Pan Control
- LCD Displays
- Chapter 30. Outputs
- Outputs on Channel Banks
- GUI channel strips
- Master Section on the control surface
- Output metering
- Bus trim (GUI only)
- Compressor (Dynamics)
- EQ (Equaliser)
- Mute, safes, level and solo
- Output channel name
- Output channel source/destination (GUI only)
- Stereo linking
- Output Configuration Patching
- Safes
- Insert
- Output channel delay
- Processing Order
- Mixes
- Masters
- Outputs macro interrogation control
- Flexi-Aux
- Chapter 31. GUI Menu (Side Bar Menu)
- Chapter 32. Configuring a virtual soundcheck
- Chapter 33. Manchino (Multi Edit Page)
- Chapter 34. Update Manager
- Chapter 35. Channel AI
- Chapter 36. Specifications
173 HD96-24-CC-TP User Manual
Dynamic EQ
The dynamic EQ is a 4-band parametric dynamic equaliser, which is able to provide frequency selective compression or expansion. The dynamic EQ features
proportional-q lters that, when boosting or cutting by small amounts, reduce the bandwidth of the lter compared to the setting at maximum cut/boost. Filter
coecients are calculated at the audio rate to provide a lightning fast attack time, which is essential for transparent operation. Each band features a full-band EQ type
that switches out the EQ lter so that the band operates as a non-frequency selective, or 'full-band' compressor/expander. The Fixed button turns any dynamic EQ
band into a non-dynamic EQ if required. The amount of gain is xed as set by the controls.
Flexible routing options allow for the following conguration modes:
1. One chain of stereo 4-band processing.
2. Two chains of stereo 2-band processing.
3. Four segments of stereo single-band processing.
Item Control Function
1 Close Eect Closes the currently open eect.
2 Input meter 20 LEDs, which show input metering.
3 Comp Gain reduction Meter 20 LEDs, which show the selected band gain reduction metering.
4 EXP Expansion Meter 20 LEDs, which show the selected band expansion metering.
5 Threshold
Turn to set the signal threshold level above (or below) which the eect is to take place. Turning
anti-clockwise reduces the signal level needed to exceed the threshold, and therefore increases
sensitivity. Signal’s exceeding threshold initiate the selected processing. Turning clockwise increases
the signal level needed and reduces sensitivity. When set fully clockwise, the threshold is set to
+20dBu.
6 Freq Frequency
Turn to set the centre frequency of the dynamic activity. Note that the range of each band is 40 Hz
to 18 kHz
7 Ratio Sets the Ratio for compression or Expansion
8 Width
Controls bandwidth or ‘Q’. Turn clockwise to widen or defocus the aected band of frequencies. Turn
anti-clockwise to narrow or sharpen the aected band.
9 Bell Switches the selected band to a bell shape.
10 LF Shelving Switches selected band to a Low Frequency shelving response
11 HF Shelving Switches selected band to a High Frequency shelving response
12 Flat Switches selected band to a at (wide-band) response.