Manual
Table Of Contents
- HD96-24 Overview
- Chapter 1. Introduction
- Chapter 2. HD96-24 Overview
- Chapter 3. System Setup
- Initial set-up procedure
- Unpacking the equipment
- Ventilation
- Racking the I/O
- Connection instructions
- System components
- Powering the system
- Switching on the HD96-24
- To switch off the HD96-24 surface
- Setting up the ID of the unit(s)
- To set up the ID of a I/O unit
- I/O Box Update
- Connection to the internet
- Hardware Connections
- Chapter 4. Before You Start
- Chapter 5. About the Control Surface
- Chapter 6. Navigation
- Navigating via the surface detail area
- Navigating via the GUI Menu Bar
- Side Bar Menu
- Widgets and Rotary Controls
- Workflow Modes Overview
- Overview
- Side Bar Pop Op Display
- Tags and Pops
- Clipping Channels
- Bus Setup and Outputs Management
- Meter Bridge
- Channel View
- Console View
- FOH View
- Automation View
- Navigating via Touch Screen Faders
- Navigating via the Layer Overview/Channel Strips area
- Navigation via Global Assignable Shortcuts area
- Navigation via Pinned Fader and Assignable Controls
- Flip Mode
- One Shot Pot
- Clipped Channels, fault finding a problem channel
- Console Layout Configuration (Navigation)
- Creating a Custom Layout
- Chapter 7. Patching
- Chapter 8. Basic Operation
- Scene and show management (Automation)
- Clear the Console
- Saving and Loading show files to a USB memory stick
- Saving and Loading show files to the mCloud
- Save & Mark
- Rollback
- Load Options
- Automate patching preferences:
- Naming Page
- Channel Tags
- Channel Configuration (Config)
- Setting a Pre-Amp’s input gain
- Linking & Stereo
- Patching
- Direct Output
- Options
- Configuration Pages for Outputs
- Linking & Stereo (Outputs)
- Patching (Outputs)
- Direct Input
- Options
- Oscillator (Output Widget)
- Setting the HPF and LPF
- Input equalisation
- True Audition
- Output processing
- Input Dynamics Processing (Dynamics Section)
- Using VCA & POP groups
- How to configure a VCA/POP group:
- Alternative way to assign VCA/POP groups
- Routing to master stereo outputs
- Manchino Multi Edit Page (Basic introduction)
- Security (locking mode)
- Chapter 9. Stereo Linking
- Chapter 10. Panning
- Chapter 11. Soloing
- Chapter 12. Chapter 12: Muting
- Chapter 13. Monitors and Shout Configuration
- Chapter 14. Graphic EQ (GEQ)
- Chapter 15. Internal Effects
- Effects overview
- Working with channel inserted effects
- Effects Browser
- Effect Rack
- Effect Sub-slots
- Effects Rack Safes
- FX Mode
- Effect Programs
- Reverbs:
- TC Electronic VSS4 Reverb
- TC Electronic VSS3 Reverb
- TC M350
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Delays:
- Midas Delay
- Stereo Delay
- TC 2290 Delay
- KT 1176 Limiting Amplifier
- KT Bus Compressor
- R-Comp
- Smart Dynamics Processor
- Dual De-Esser
- DSR De-esser
- PIE (Prime Input Expander)
- Stressor Compressor
- Dual Band & Brickwall limiter.
- Midas U Flange
- Midas U Phase
- Pitch Shifter
- Chorus
- Rotor Motor
- Distortion/Exciter:
- Enlightenment Bass
- Glow
- Tape Saturation
- UNCL.HD MULTIBAND DISTORTION
- M Harmonics
- Chapter 16. Talk and Mute Groups
- Talk Groups
- Mute groups
- Using copy and paste
- Copy and Paste rules and restrictions
- Channels Versus Scenes
- Copy and Paste Parameters
- About the Assignable Rotary
- Controlling the Assignable rotary controls
- Pinned Channels
- Flip Target
- Global Assignable Shortcuts
- Assignables Types: Automation
- Assignables Types: Groups.
- Chapter 19. Automation (Scenes and Shows)
- Chapter 20. Show Editor (Recall and Store Scope)
- Chapter 21. Events (Automation)
- Chapter 22. Crossfade Events
- Chapter 23. TBC
- Chapter 24. File Management
- Chapter 25. Multiple Consoles and Other Devices
- Chapter 26. Preferences (Console Configuration)
- Chapter 27. Delay Compensation (Latency)
- Chapter 28. Panel Connections
- Chapter 29. Inputs
- Input channel routing
- Input channel areas of the control surface
- Input Widget Area
- The following processing sections are available:
- Channel View Workflow
- Side Bar Area
- Channel View
- Sends Overview
- Send Detail Area
- Input channel delay
- Aux return mode
- Effects Insert
- Input Metering
- Input Inserts
- Options - Processing Order
- Safes
- Mic Amp Input Gain
- Dynamics and mode descriptions
- Compressor
- Compressor modes
- Corrective mode (exponential peak - fast)
- Adaptive mode (exponential RMS - accurate)
- Creative mode (linear peak - slow)
- Vintage mode (adaptive peak - bright)
- Compressor Graph
- Ratio
- Knee
- Gate
- Ducker
- Sidechain
- EQ
- Phase (All Pass Filter) Controls
- Mixes
- Input channel Pick Off points
- Masters Section and Pan Control
- LCD Displays
- Chapter 30. Outputs
- Outputs on Channel Banks
- GUI channel strips
- Master Section on the control surface
- Output metering
- Bus trim (GUI only)
- Compressor (Dynamics)
- EQ (Equaliser)
- Mute, safes, level and solo
- Output channel name
- Output channel source/destination (GUI only)
- Stereo linking
- Output Configuration Patching
- Safes
- Insert
- Output channel delay
- Processing Order
- Mixes
- Masters
- Outputs macro interrogation control
- Flexi-Aux
- Chapter 31. GUI Menu (Side Bar Menu)
- Chapter 32. Configuring a virtual soundcheck
- Chapter 33. Manchino (Multi Edit Page)
- Chapter 34. Update Manager
- Chapter 35. Channel AI
- Chapter 36. Specifications
124 HD96-24-CC-TP User Manual
Proportional-Q Vs Constant-Q Response
KLARK TEKNIK’s enhanced Proportional-Q (Prop) equalisation oers key advantages over standard Constant-Q (Con) graphic equalisers. The Con response boosts or
cuts an increasingly wide band of frequencies, resulting in more of the frequency spectrum being lost when using the Con equaliser to eliminate problem frequencies.
In contrast, with a Prop response, at low amounts of cut or boost the width of the lter is relatively broad allowing for gentle contouring of the frequency spectrum,
but becomes progressively narrower as the amount of boost or cut is increased, giving a more ‘focused’ response ensuring that problem frequencies can be attenuated
quickly and eectively. At the same time, the enhanced Prop equalisation response used on the GEQ minimises interaction between adjacent frequency bands,
allowing subtle tonal correction without frequency response ripple, so that more of the musical content is preserved.
Note: At high gain settings, a proportional-Q equaliser “automatically” increases Q for more dramatic problem solving such as suppression of feedback or
unwanted resonances.
GEQ Filters
The 12 dB/oct high-pass lter features a 20 Hz to 500 Hz range and is invaluable for the smooth rejection of unwanted low and subsonic frequencies, particularly
relevant for use with modern compact wedge monitors. The 12 dB/oct low-pass lter features a 2 kHz to 20 kHz range and can be used to improve intelligibility by
tailoring the upper frequency response to match that of the monitor speaker.
The two 17 dB notch lters feature overlapping frequency ranges of 20 Hz to 2 kHz and 200 Hz to 20 kHz. The notch lters allow the surgical removal of resonances and
feedback with minimal eect on the rest of the program material, and fast control of ‘between fader’ frequencies. The ability to overlap the notch lters, both with
each other and with the graphic equaliser bands, allows very deep notches to be created. Up to 46 dB of attenuation is possible when using the notch lters in
conjunction with the graphic equaliser bands.
GEQ Patching
There are serveral ways to patch a GEQ.
• • Insert a GEQ on a path by navigation to either the Home, FOH or Channel View workows. Select the path you wish the GEQ to be inserted on and add the GEQ in
the eects insert page.
• • Add a GEQ in the FX Rack page. The GEQ will now also be available In the Patching Workow to patch as desired.