Manual
Table Of Contents
- HD96-24 Overview
- Chapter 1. Introduction
- Chapter 2. HD96-24 Overview
- Chapter 3. System Setup
- Initial set-up procedure
- Unpacking the equipment
- Ventilation
- Racking the I/O
- Connection instructions
- System components
- Powering the system
- Switching on the HD96-24
- To switch off the HD96-24 surface
- Setting up the ID of the unit(s)
- To set up the ID of a I/O unit
- I/O Box Update
- Connection to the internet
- Hardware Connections
- Chapter 4. Before You Start
- Chapter 5. About the Control Surface
- Chapter 6. Navigation
- Navigating via the surface detail area
- Navigating via the GUI Menu Bar
- Side Bar Menu
- Widgets and Rotary Controls
- Workflow Modes Overview
- Overview
- Side Bar Pop Op Display
- Tags and Pops
- Clipping Channels
- Bus Setup and Outputs Management
- Meter Bridge
- Channel View
- Console View
- FOH View
- Automation View
- Navigating via Touch Screen Faders
- Navigating via the Layer Overview/Channel Strips area
- Navigation via Global Assignable Shortcuts area
- Navigation via Pinned Fader and Assignable Controls
- Flip Mode
- One Shot Pot
- Clipped Channels, fault finding a problem channel
- Console Layout Configuration (Navigation)
- Creating a Custom Layout
- Chapter 7. Patching
- Chapter 8. Basic Operation
- Scene and show management (Automation)
- Clear the Console
- Saving and Loading show files to a USB memory stick
- Saving and Loading show files to the mCloud
- Save & Mark
- Rollback
- Load Options
- Automate patching preferences:
- Naming Page
- Channel Tags
- Channel Configuration (Config)
- Setting a Pre-Amp’s input gain
- Linking & Stereo
- Patching
- Direct Output
- Options
- Configuration Pages for Outputs
- Linking & Stereo (Outputs)
- Patching (Outputs)
- Direct Input
- Options
- Oscillator (Output Widget)
- Setting the HPF and LPF
- Input equalisation
- True Audition
- Output processing
- Input Dynamics Processing (Dynamics Section)
- Using VCA & POP groups
- How to configure a VCA/POP group:
- Alternative way to assign VCA/POP groups
- Routing to master stereo outputs
- Manchino Multi Edit Page (Basic introduction)
- Security (locking mode)
- Chapter 9. Stereo Linking
- Chapter 10. Panning
- Chapter 11. Soloing
- Chapter 12. Chapter 12: Muting
- Chapter 13. Monitors and Shout Configuration
- Chapter 14. Graphic EQ (GEQ)
- Chapter 15. Internal Effects
- Effects overview
- Working with channel inserted effects
- Effects Browser
- Effect Rack
- Effect Sub-slots
- Effects Rack Safes
- FX Mode
- Effect Programs
- Reverbs:
- TC Electronic VSS4 Reverb
- TC Electronic VSS3 Reverb
- TC M350
- Ambience Reverb
- Vintage Room Reverb
- Chamber Reverb
- Hall Reverb
- Plate Reverb
- Delays:
- Midas Delay
- Stereo Delay
- TC 2290 Delay
- KT 1176 Limiting Amplifier
- KT Bus Compressor
- R-Comp
- Smart Dynamics Processor
- Dual De-Esser
- DSR De-esser
- PIE (Prime Input Expander)
- Stressor Compressor
- Dual Band & Brickwall limiter.
- Midas U Flange
- Midas U Phase
- Pitch Shifter
- Chorus
- Rotor Motor
- Distortion/Exciter:
- Enlightenment Bass
- Glow
- Tape Saturation
- UNCL.HD MULTIBAND DISTORTION
- M Harmonics
- Chapter 16. Talk and Mute Groups
- Talk Groups
- Mute groups
- Using copy and paste
- Copy and Paste rules and restrictions
- Channels Versus Scenes
- Copy and Paste Parameters
- About the Assignable Rotary
- Controlling the Assignable rotary controls
- Pinned Channels
- Flip Target
- Global Assignable Shortcuts
- Assignables Types: Automation
- Assignables Types: Groups.
- Chapter 19. Automation (Scenes and Shows)
- Chapter 20. Show Editor (Recall and Store Scope)
- Chapter 21. Events (Automation)
- Chapter 22. Crossfade Events
- Chapter 23. TBC
- Chapter 24. File Management
- Chapter 25. Multiple Consoles and Other Devices
- Chapter 26. Preferences (Console Configuration)
- Chapter 27. Delay Compensation (Latency)
- Chapter 28. Panel Connections
- Chapter 29. Inputs
- Input channel routing
- Input channel areas of the control surface
- Input Widget Area
- The following processing sections are available:
- Channel View Workflow
- Side Bar Area
- Channel View
- Sends Overview
- Send Detail Area
- Input channel delay
- Aux return mode
- Effects Insert
- Input Metering
- Input Inserts
- Options - Processing Order
- Safes
- Mic Amp Input Gain
- Dynamics and mode descriptions
- Compressor
- Compressor modes
- Corrective mode (exponential peak - fast)
- Adaptive mode (exponential RMS - accurate)
- Creative mode (linear peak - slow)
- Vintage mode (adaptive peak - bright)
- Compressor Graph
- Ratio
- Knee
- Gate
- Ducker
- Sidechain
- EQ
- Phase (All Pass Filter) Controls
- Mixes
- Input channel Pick Off points
- Masters Section and Pan Control
- LCD Displays
- Chapter 30. Outputs
- Outputs on Channel Banks
- GUI channel strips
- Master Section on the control surface
- Output metering
- Bus trim (GUI only)
- Compressor (Dynamics)
- EQ (Equaliser)
- Mute, safes, level and solo
- Output channel name
- Output channel source/destination (GUI only)
- Stereo linking
- Output Configuration Patching
- Safes
- Insert
- Output channel delay
- Processing Order
- Mixes
- Masters
- Outputs macro interrogation control
- Flexi-Aux
- Chapter 31. GUI Menu (Side Bar Menu)
- Chapter 32. Configuring a virtual soundcheck
- Chapter 33. Manchino (Multi Edit Page)
- Chapter 34. Update Manager
- Chapter 35. Channel AI
- Chapter 36. Specifications
109 HD96-24-CC-TP User Manual
To be eligible for SIP muting, channels must be input channels and set up to solo to the solo A bus; channels with any other combination cannot be subjected to SIP
muting. Channels eligible for SIP muting that are currently or subsequently muted by a means other than SIP (that is, local button press, auto-mute or scene recall)
remain muted, regardless of the SIP status. On removal of the overriding mute, the mute is restored according to the current SIP status.
Solo Management
The solo signals can be selected for each monitor system (A and B) to be AFL, PFL, additive or interlock cancelling. PFL and AFL audio busses may accept injected
external signals, and two-level controls to make adjustments.
PFL and AFL levels are adjustable via the PFL level and AFL level controls.
The function of the buttons in each solo section is as follows:
1. Solo Dim – Turns the level of the solo bus down in the monitor bus in order to hear talk signals.
2. Input PFL – Sends mono pre-fader listen (PFL) solo bus input signals to headphones and local monitor outputs. With PFL switch disabled (LED extinguished),
stereo after fader listen (AFL) solo bus signals are sent to headphones and local monitor outputs. If an input is linked or made stereo the pan position in the stereo
image is followed in the monitor bus.
3. Output PFL – Sends mono pre-fader listen (PFL) solo bus output signals to headphones and local monitor outputs. With PFL switch disabled (LED extinguished),
stereo after fader listen (AFL) solo bus signals are sent to headphones and local monitor outputs. If an output is linked or made stereo the pan position in the
stereo image is followed in the monitor bus.
4. Solo Add – Allows multiple channel access to solo busses. When solo Add mode is o, pressing a solo switch cancels any currently active solos. Multiple solos (for
example, stereo left and right signals) can be monitored in this mode provided solo switches are pressed at approximately the same time. When solo Add mode
is on, auto-cancelling is defeated, which allows multiple channel or output soloing. In this mode, input solos have priority over outputs and VCA solos and will
temporarily override them. When the input solo is cancelled, output solo or VCA solos are reinstated.
5. Solo Clear – This switch illuminates when a solo switch is active in its monitor section and, when pressed, clears any solo switches in that section.