Operation Manual
LED indicators 9
DL431 Mic Splitter
Operator Manual
LED indicators
5 Y and X Ethernet control EtherCon® XLRs for connection of ‘tunnelling’ 
Ethernet. For a description of the LEDs, see “LED indicators” on page 9.
6 USB slave (type B) and host (type A) sockets for connection of a laptop 
PC.
7 Two mains IEC sockets with on/off switches.  Although both are connected 
to the mains, one is a dual redundant spare that can automatically switch in 
if the other fails.
Item Description
1 Green check LED illuminates to show when a channel is selected on a 
console.
2 Red 48V LED illuminates to show that 48V phantom voltage is on.
3 Green and red LEDs on both the X and Y AES50 audio - A and B sockets, 
indicate the following:
• Pulsating green with red extinguished = valid audio and valid aux data; 
active link.
• Constantly illuminated green with red extinguished = valid audio and 
valid aux data; standby link.
• Green extinguished with red illuminated = no audio; link has failed.
4 Green LEDs on both the Ethernet control X and Y sockets have the same 
function as those in the Ethernet control panel on the front of the unit (see 
“Ethernet control panel” on page 4).
Item Description
1
2
4
4
3
3
3
3