User Guide

solo
1
2
3
4
5
6
7
8
9
10
group
assign
switches
1&2
3&4
5&6
7&8
9&10
11&12
13&14
15&16
MIDAS
safe
isolate
10
10
5
5
0
20
30
40
50
60
dB
The SOLO switch sends the
input channel signal to the PFL
mono and AFL stereo busses. If
the switch is pressed for a short
time it will latch on or off, but,
if it is held on for more than 1
second the latching is disabled
and when the switch is released
the channel solo will turn off.
The ISOLATE switch
disconnects the input channel
from automation scene recall.
Scene storage is still active.
The SAFE switch disconnects
the input channel mute from
the 8 auto mute busses.
The GROUP ASSIGN
SWITCHES 1 to 10 are under
automation control and
perform 3 major functions:-
The VCA INPUT fader gives
continuous adjustment of the
input channel level from +
10dB to off.
14
i. They are used to assign the
input channel post fader
signal to the 16 AUDIO
groups via the pan control.
ii. They are used to assign the
input channel to the 10 VCA
sub groups.
iii. They are used to assign
the input channel to the 8 auto
MUTE groups.
The function of these
switches is globally selected
by pressing the large AUDIO,
VCA or MUTE switches on
the AUTOMATION
CENTRAL CONTROL
panel. A fourth large switch
LOCK is used to disable all
the input channel group
assign switches throughout
the console so as to avoid
accidental operation. It is still
possible to view the switch
status of all three group types
when in this mode.