being measured by the meter is also available for pre-fade listen.
4) Matrix Output Mute. This cuts the Matrix Output from the module. A
red LED indicates when Matrix Output Mute is in operation.
5) Matrix Output Fader. The Penny and Giles fader controls the level of the
Matrix Output from the module.
6) Routing buttons. The eight Routing buttons send the input of the module to
any or all of the eight Matrix Outputs. Routing is active when the button is
depressed and the yellow LED is glowing.
7) Routing Level Control. Each of the eight Routing Level Controls governs
the amount of signal from the module sent to the respective Matrix Output, from
minus infinity dB to +10dB. Note that these controls affect the signal sent FROM
the module to the Matrix Outputs, not signals coming into the module.
8) Output PFL buttons. Any input or output to or from the XL88 can be
selected for Pre-Fade Listen. With the Meter Changeover button of any module
unselected, the PFL button will access the INPUT to that module, before the
Direct Output level control. With the Meter Changeover button selected, and
the LED glowing, PFL will access the Matrix Output from the module.