User Guide
The MON MUTE switch mutes the
monitor input channel signal path at all
points after the insert send. The switch
can be controlled from snapshot
automation.
The FOH MUTE switch mutes the front
of house input channel signal path at all
points after the insert send. The switch
can be controlled from snapshot
automation.
The MON and FOH FADERS give
independent adjustment of the monitor
and front of house input channel levels
from + 10dB to off.
The “module disable” is not intended for
normal use, however, if the automation
systems fail, this switch can be used to
stop unwanted scene updates and set the
module to a default state.
The 10 ASSIGN led's are used to show
the status of the VCA-FOH, VCA-
MON, and AUDIO group assignments.
The central controller MODE switches
toggle through the four available states
(the fourth state being AUX where status
is displayed close to the aux controls).
The SET switch is used to programme
the channel AUX, VCA-FOH,
VCA_MON and AUDIO group
assignment. The central controller
MODE switches and ASSIGN keys
select the desired assignment function
and the SET switch toggles the channel
on and off with each alternate press.