Set store/restore menu
3.10.3 Memory depth
Memory depth means the oscilloscope’s capacity of storing sample points. For example, the
store depth is 120K, and it says it can store 120k sample points.
Press and to enter the adjustment menu of store depth, if it is a single
channel, it can be set to2.4K, 24k, 240k, and a dual channel can be set to1.2k,12K, 120k,and
press to adjust the value of store depth.
3.10.4 Dynamic record
Note: Need to be updated to get this function.
Dynamic record can easily record the waveform and memory operation steps. Only after
identifying the USB device can start dynamic record. U device icon will be displayed at
upper right corner if U device is connected and ‘Dynamic record’ turn white(grey
previously)(note: system divides U device into four store area automatically, based on the
need to store the four different information into separate areas. if the record area has