User Manual
Table Of Contents
- About This Manual
- Copyright
- Proprietary Material
- Quality Certification
- Regulatory Status
- Conventions
- Symbols Used
- Warranty Information
- Introduction
- Product Description
- Routine Operation
- 3.1 Chapter Overview
- 3.2 Overview of Controls, Indicators, and Connectors
- 3.3 Preparing for Operation
- 3.4 Using the STRATA TX Screens
- 3.5 TXU and/or TCU Monitoring Operations
- 3.5.1 Using the Monitor Screens in MPEG Output Mode
- 3.5.2 Using the Monitor Screens in Ext IF Input Mode
- 3.5.3 Using the Monitor Screens in COFDM - IF Mode
- 3.5.4 Using the Monitor Screens in COFDM ASI In Mode
- 3.5.5 Using the Monitor Screens in Analog - IF Mode
- 3.5.6 Using the Monitor Screens in DVB-S Mode
- 3.6 TXU and/or TCU Control Operations
- 3.7 Front Panel vs. STRATA TX Configurator Settings
- Table 3-1: Front Panel vs. Configurator Settings
- Troubleshooting
- Channels & Frequencies
- A.1 Appendix Overview
- A.2 Initial Factory Presets
- A.2.1 3.4 to 3.8 GHz Channel Plan
- A.2.2 4.4 to 5.0 GHz Channel Plan
- A.2.3 6.4 to 7.1 GHz Channel Plan
- A.2.4 6.9 to 7.5 GHz Channel Plan
- A.2.5 7.4 to 8.0 GHz Channel Plan
- A.2.6 7.8 to 8.5 GHz Channel Plan
- A.2.7 8.2 to 8.9 GHz Channel Plan
- A.2.8 10.0 to 10.7 GHz Channel Plan
- A.2.9 10.5 to 11.2 GHz Channel Plan
- A.2.10 10.8 to 11.5 GHz Channel Plan
- A.2.11 12.7 to 13.25 GHz Channel Plan
- Glossary
- Specifications
Routine Operation 3-19STRATA TX Operator’s Guide/Tech Ref Manual
Figure 3-15: 75 Ohm Coax Option
9. Press control switch to change Power Off to read
Power On, as required.
10. Set the TXU PWR switch to I (on).
11. The normal power-up sequence is as follows:
- The Status LED above the PWR switch should
illuminate and should change colors from red, to
green, to amber, and finally remain green.
- The alphanumeric display should light up and quickly
display a self-test screen, then the version of the
installed firmware, and finally the Main Screen.
Some typical screens are shown in Figure 3-16. The
exact screens will vary depending on installed
hardware.
- The TXU will typically power up using the last settings
in use when power was turned off.
- If the TXU does not power up normally, refer to the
“Troubleshooting” Chapter on page 4-1.
75 Ohm Coax
Power Off
Figure 3-16: Typical TXU Power Up Screens - Co-Located
TXU and TCU
Power Down
1. Set the TXU PWR switch to 0 (off).
2. Set the TCU PWR switch to 0 (off).
3. If the TCU/TXU is powered from the optional ACU, set
the ACU power switch to 0 (off).
If the TCU/TXU is powered from a source other than
an ACU, turn that power source off.
STRATA TX
V X.X.X
Preset 1
0.00W
Radio Version
Main Screen