User Manual Part 1

Routine Operation 3-48MTX5000 User and Technical Manual
Figure 3-96: PA Voltage Adjust Setup Screen
Notes
If using the function keys and SEL key to select the
Start option button, go to step 8.
If using the touch screen, go to step 9.
8. Select the Start option button and observe the Start
option button becomes active (blue). See Figure 3-97.
Figure 3-97: PA Voltage Adjust Setup Screen - Start
<-Previous
Start
Factory->
This process will allow you to calibrate
the PA DC voltage for each specific
frequency band. Once you have the
Radio connected to the ODU
and are ready to start calibration,
Press the START Button below
Main
Start
<-Previous Factory->
Welcome to the PA Voltage Adjust Setup
Screen!
This process will allow you to calibrate
the PA DC voltage for each specific
frequency band. Once you have the
Radio connected to the ODU
and are ready to start calibration, press
the START Button below
Main
Notes
When the Start option button is selected in the
following step, calibration will begin and the Start
option button indicator will change from green to
red.
It will take approximately 30 seconds for the
calibration process to be completed.
When calibration is complete, the Start option
button indicator will change from red to green.
9. Select the Start option button and observe the Start
option button indicator turns red and the Starting the
Calibration... message is displayed. See Figure 3-98.
Figure 3-98: Starting Calibration
Note
Do not select the Factory option button. The
Factory option button is used for factory test only.
10. When calibration is complete, observe the Calibration
Successful message is displayed. See Figure 3-99
on page 3-49.
Start
Starting the Calibration...
<-Previous Factory->
Main