User Manual Part 1
Routine Operation 3-44MTX5000 User and Technical Manual
Note
If the Preset being monitored is a digital COFDM,
LMS-T, or DVB-S Preset, go to step 25.
If the Preset being monitored is a digital IP Preset,
go to step 26.
25. When review of the PID Status-2 screen is complete,
select the Main option button and observe the Main
screen is displayed. Procedure is complete.
26. When review of the PID Status-2 screen is complete,
select the Back option button and observe the PID
Status screen is displayed.
27. Select the Back option button and observe the
COFDM Mode Status screen is displayed.
28. Select the IP Transfer option button and observe the
IP Status screen is displayed. See Figure 3-86.
Figure 3-86: IP Status Screen - Typical
29. When review of the IP Status screen is complete,
select the Main option button and observe the Main
screen is displayed. Procedure is complete.
IP Status
Back
IP Transfer Mode
Max Bit Rate 19.350 Mbps
12.441 Mbps
IP + Video
Main
Video Bitrate
IP Rate
5.2 Mbps
3.6.13 Perform PA Voltage Adjust Setup
The procedure required to calibrate the PA DC voltage for each
Standard ODU (RF Unit) is contained in the following steps.
This procedure is to be performed for Standard ODUs only.
Do not perform this procedure for High Power ODUs. The
PA voltage for High Power ODUs is fixed and cannot be
adjusted.
CAUTION
To avoid potential software hang-ups,
always ensure the ODU is connected to the
IDU before attempting to perform this
procedure.
Do not attempt to perform this procedure if
the ODU is not connected to the IDU, as the
software will hang up.
CAUTION
To avoid potential software hang-ups, check
the Main screen ODU status indicator and
verify no major faults exist in the ODU.
If faults exist in the ODU, they must be
corrected prior to performing this procedure.