User Manual Part 1

Advanced Operations 5-15MTX5000 User and Technical Manual
Figure 5-26: Frequency Pull-Down Menu - Typical
49. Use the FREQUENCY pull-down menu to select the
Custom option and observe the FREQUENCY option
button becomes active (not greyed-out).
50. Select the FREQUENCY option button and observe
the numeric keypad is displayed. See Figure 5-27.
Figure 5-27: Numeric Keypad
51. Enter the custom audio frequency required (range is
4830 kHz to 8590 kHz), select the ENT key, and
observe the AUDIO CH4 screen is displayed.
AUDIO CH4
Back
ENABLE On FREQUENCY
PRE-EMPHASIS On
4830 kHz
5200 kHz
5800 kHz
6200 kHz
4830 kHz
Main
1 2 3
4
7
5 6
8 9
CLR
0
ESC
ENT
52. Select the Back option button and observe the FMT
SETUP screen is displayed.
53. Select the Back option button and observe the
Operation Mode screen is displayed.
See Figure 5-
28.
Figure 5-28: Operation Mode Screen
Note
When the Save As Preset screen is displayed in
the following step, the Preset Text and Save text
boxes will display the name and identification of the
analog Preset currently being used as the analog
“make-from” for this custom Preset.
54. Select the Save As Preset option button and observe
the Save As Preset screen is displayed. See
Figure 5-29 on page 5-16.
Operation Mode
Back
COFDM FMT ASI
IP
SCM
LMS-T
Save As Preset
DVBS
MPEG
Main