User Manual Part 1
Routine Operation 3-72MTX5000 User and Technical Manual
Figure 3-148: Remote Screen Display - Typical
3. Select the Main tab RF Power pull-down menu and
select the RF Power pull-down menu option required.
3.8.9 Monitor Alerts
The procedure required to monitor the current alarm status of the
ODU, IDU, and summary (SUM) alarms is contained in the
following steps.
The ODU, IDU, and SUM status indicators will be green if no
alarms are present in the system. If a minor IDU and/or ODU
alarm is detected that does not adversely affect transmit
operations, the applicable status indicator will be yellow. If a
major alarm is detected in either the IDU or ODU that adversely
impacts transmit operations, the IDU or ODU status indicators
will be red.
The SUM status indicator will display a red status indicator if the
IDU and/or ODU is reporting at least one major alarm that
adversely affects transmit operations.
The SUM status indicator will not display a red status indicator
for all alarm conditions reported by the ODU or the IDU. Only
alarm conditions that are considered major to the operation of
the transmitter will change the state of the SUM status indicator
status indicator to red.
Note
This procedure may be used to select either the
ODU, IDU, or SUM option buttons to review the
current alert status of the MRX5000 System.
1. Verify the MTX5000 system is powered up and the
system is in the remote operating mode.
2. Observe the Remote screen is displayed on the
remote PC display. See Figure 3-149.
Figure 3-149: Remote Screen Display - Typical
3. Observe the ODU, IDU, and SUM status indicators.