User's Manual
Page 66
NewStream User Guide and Technical Manual
Satellite Status Page [Continued]
Symbol Rate
Symbol Rate [aka baud or modulation rate] is the number of symbol changes [i.e.
waveform changes or signalling events] made to the transmission medium per second
using a digitally modulated signal or a line code. The Symbol Rate is expressed in Mega
symbols/second [Ms/s]. The valid range is 1.0000-36.0000 Ms/s.
Roll Off
Roll-off describes the steepness of a transmission function with frequency, in connection
with fi lter circuits in the transition between a passband and a stop band.
Values of Roll-off are expressed in percentages, ranging from:
• 35%
• 25%
ASI Bitrate
The Video Bitrate displayed ranges from 0 to 99.999 Mb/s.
Modify Presets Page
While viewing a Status page, click the Setup button to display the drop-down menu. The
menu displays the following options:
• Modify Presets
• Frequency Plans
• NewStream Settings
• Manual Mode
• License Manager
Select Modify Presets to begin creating custom confi gurations for SNG, ENG and CNG
transmission in the page shown in Figure 33. NewStream is confi gured with three factory
default presets with the ability to create up to 99 custom presets. You can modify each
preset name and its type in the Modify Presets page, as shown in the fi gure. You can
confi gure additional settings for each custom preset by clicking the
confi gure preset
icon. Presets marked with the padlock symbol
are factory defaults and cannot be
modifi ed but can be used as a template for your custom presets. The active preset is
highlightedhighlighted.
In the Modify Presets page you can use the Export
tool to save custom presets to a
fi le or to other IDUs. Additionally, you can import presets from a directory on your PC, to
another IDU or to a USB fl ash drive using the
tool which loads custom presets from
a fi le. This feature can not be implemented while the system is transmitting.