Confi guring Cellular Communications
When confi guring Cellular Presets, you must type an IP Address to designate the
destination for the cellular video stream. The LiveGear Receiver’s [LGR] IP address
is the destination to communicate with the NewStream IDU. You must also designate
the LGR Port and Channel numbers for the cellular video stream. Use the LGR Port
and Channel numbers assigned for communication with NewStream. This information
can be added to the CNG Presets that you confi gure with the Web interface in
Remote mode. Refer below to the following Initial Setup section to assist your Cellular
confi guration endeavors.
As mentioned for Microwave control, set the IDU to Remote Mode and go to the
Modify Presets Web interface to make unique copies of the CNG Presets in order to
create customized presets that your operators will use during broadcast. For more
information refer to the
Modify Presets section. For Remote Control operation see
the sections below: Confi guration Mode touchscreen and Remote Operation Using the
Web Interface
.
Initial CNG Setup
It is recommended that you pre-confi gure the transmitter and receiver together in the
studio to ensure that the initial settings are analogous. It is also suggested that you
test the system with a live video feed prior to sending a transmitter team to a remote
location. The initial steps for the confi guration procedure are as follows:
Live Gear Receiver [LGR-1000] - Refer to the LiveGear Receiver User and Technical
Manual for more information.
Connect AC Power Supply.
Connect Video Output [SD/HD OUT / 1 to monitor].
Connect Ethernet Cable [WAN port to router].
Set the rear Power Supply switch to On position.
NewStream Transmitter
Install SIM cards [up to 6] in the Cellular ODU if not pre-installed - refer to
Appendix A for further information.
Set IDU to Remote control.
Connect video source [SD or HD SDI Input on the rear panel - refer to Figure 6].
Connect AC power supply [on the rear panel - refer to Figure 6].
Steps to Stream Video in CNG Mode:
1. Connect a laptop to the 4 port switch on the rear panel and apply power to the
LGR by setting the Power Supply rocker switch on the rear panel and by pressing
the front panel Power push button. Check the LCD to ensure that the initialization
process has completed.
2. Browse to the default IP address of the LGR on the LAN at http://192.168.2.200.
Log in using the UID/PW: admin/admin.
3. Browse to Setup > Network Settings
4. Set your IP address information in the WAN Confi guration box and click Save.