Specifications
05-4055A01, Rev. D GE MDS entraNET Reference Manual 87
Figure 3-51. Reprogramming Menu
• TFTP Host Address—IP address of the host computer from which
to get the file. [Any valid IP address]
• Firmware Filename—Name of file to be received from the TFTP
server. Verify that this string corresponds to the TFTP directory
location. May require a sub-directory; for
example: entranet/bkrfto-1_0_0.gpk. [Any 40-character alphanumeric
string
]
• TFTP Timeout—Time in seconds the TFTP server waits for a
packet ACK (acknowledgment) from the transceiver before sus-
pending the file transfer. [10 to 120 seconds; 30]
• Retrieve File—Initiate the file transfer from the TFTP server.
Placed into inactive firmware position in the transceiver
non-volatile memory. [
Y, N]
• Image Verify—Initiate the verification of the integrity of firmware
file held in the radio.
• Image Copy—Initiate the copying of the active firmware into the
inactive image.
• Reboot Device—Initiate restarting the transceiver. This interrupts
data traffic through this radio and the network, if performed on
an AP. Use this command to toggle between firmware images.
•
Current Firmware—Shows the current firmware revision level.
3.11.2 Configuration Scripts Menu
A Brief Description of Configuration Files
If you plan to have more than a few transceivers in your network, you
may want to use the Configuration Scripts Menu (Figure 3-52) to con-
figure similar radios from a common set of parameters. Over 50 cus-
tomer settings that optimize the network are saved in a configuration file