Specifications
70 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
• EndPoint Logging—This selection is used to specify whether end-
point logging is enabled or disabled. [Enabled, Disabled; Enabled]
3.8.1 Remote Management Menu
The Remote Management Menu (Figure 3-33) allows selection of a par-
ticular Remote to manage, based on the radio Unit ID number (generally
the last four digits of its serial number).
Figure 3-33. Remote Management Menu
• Remote to Manage—Radio address of the Remote to be managed
(typically a four-digit code).
• Manage Selected Remote—Displays the screen shown in
Figure 3-34. It contains several parameters that are used to set
the characteristics of Remote radios in the network.
•
Broadcast Remote Programming—Selecting this item brings up a
submenu (Figure 3-36) where you may initiate the broadcast of
new firmware images and Remote restart commands.
NOTE: Before programming a Remote radio over the air, be sure to set
ETHERNET BRIDGING (see “Bridge Configuration Menu” on
Page 51) from ALL (default) to either DISABLED or NO BROAD-
CAST/MULTICAST
.
Otherwise, you may experience sync errors, or programming
may not complete. Excessive broadcast/multicast traffic from
a connected LAN can also cause problems.