Specifications
05-4055A01, Rev. D GE MDS entraNET Reference Manual 63
Invisible place holder
Figure 3-27. Remote Serial Gateway Menu—Initial Screen
• RSG Talkback Enable (UDP IP-to-Serial)—When Talkback is
enabled and the RSG is set up for UDP mode, a message
from a Remote radio (usually a reply to a poll) is sent to the
last IP address or port that a message was received from.
[Enabled, Disabled; Enabled]
• RSG Talkback Timeout—This selection is used to set a time
limit after which, if no data has been received from the IP
host, the RSG talkback feature expires. When this happens,
the RSG reverts to its configured IP address and port for
upstream data destined for an IP host. [Time in seconds; 30]
• RSG Entries—This selection allows entry of key RSG
parameters including Unit ID, COM port setting, Mode, and
Local IP Port. This screen is shown in Figure 3-28.
• Remote Serial Wizard—This tool assists you in adding or
changing a configuration to your remote serial gateway
entries. These are the same settings contained in RSG Entries
Screen above, but the Remote Serial Wizard presents a
step-by-step series of screens with explanatory text to assist
you in making your selections.