Specifications
05-4055A01, Rev. D GE MDS entraNET Reference Manual 59
View Current Settings Screen—Serial-to-Serial Example
If you choose View Current Settings from the Serial Configuration Wizard
Menu, you see a summary screen (Figure 3-25) showing the serial con-
figuration settings. (This is the same screen that is also shown at the end
of the configuration process.) Here, you may choose the letter of an item
to change, or exit the Serial Configuration Wizard completely.
NOTE: Selecting any item other than Commit Changes and Exit Wizard
returns you to the configuration process. After making the
necessary change(s), you can use the Continue Wizard selection
repeatedly to reach the end of the configuration process, and
then exit.
Invisible place holder
Figure 3-25. Serial Configuration Current Settings Screen
(Serial-to-Serial example)
The following text explains the key settings for the Serial Configuration
Menu (serial-to-serial example).
•
Port Status—This selection is used to enable or disable the
serial data port for payload data operation. Normally,
COM1
is set to
Disabled to permit console terminal operation.
NOTE: When COM1 is enabled for data, management of the radio
through COM1 is disabled. This problem can be remedied by
typing the escape sequence + + + followed by .
This restores COM1 to console terminal mode. You must log in
again.