Specifications

24 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
hardware flow control disabled
VT100 emulation
NOTE: The exact parameters given above must be used for console
terminal communication. Improper settings are a common
cause of difficulty.
Invisible place holder
Invisible place holder
Invisible place holder
Invisible place holder
Invisible place holder
Figure 2-6. Remote Configuration Setup
3. Press several times to receive the entranet> prompt. (The
COM1/ETH LED blinks to indicate data communication.)
4. At the entranet> prompt, enter login. Press .
5. At the next prompt, enter the username (the default username is
admin). Press .
6. At next prompt, enter the password (the default password is admin).
Press . The radio is now ready to accept commands.
Set or Verify Network Address
The only setting normally required for initial checkout of a Remote
radio is the network address. All radios in a given network must be pro-
grammed with the same network address as the AP, or communication
is impossible. Follow the steps below to check the address, and program
a new one if necessary.
1. Enter the
RADIO NETADDR= command. This displays the currently
programmed network address.
2. If changes are required, enter the
RADIO NETADDR=<netaddr> com-
mand, where <netaddr> is 1-15 alphanumeric characters. (The net-
work address of the Remote radio must match that of the AP.)
3. Verify that the
LINK LED lights to indicate successful connection
with the AP. (It may take several seconds for the LED to light.)