Specifications

18 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
Invisible place holder
Figure 2-1. AP Interface Connectors
Figure 2-2 shows the interface connectors for the Remote transceiver.
Invisible place holder
Figure 2-2. Remote Interface Connectors
Invisible place holder
2.3 TEST SETUP
The following steps explain how to make connections to the transceiver
system, power it up, and set basic configuration. After these steps are
complete, the system is ready for field installation.
COM1
DCE (Console/Terminal only)
19,200 bps/8N1
No Handshaking
RS/EIA-232
COM2
DCE (Connects to serial data equip.)
9,600 bps/8N1
Full Handshaking
RS/EIA-232
PRIMARY POWER
6–30 Vdc
(800 ma @ 13.8 Vdc)
Negative Ground
ANTENNA
50Ω TNC
+30 dBm/1W Out (Max
.)
–30 dBm Input (Max.)
LAN
10-Base-T
IP/Ethernet Port
IP Address: 192.168.0.1
COM1
DCE (Console/Terminal only)
19,200 bps/8N1
No Handshaking
RS/EIA-232
PRIMARY POWER
6–30 Vdc
(600 ma @ 13.8 Vdc)
Negative Ground
ANTENNA
50Ω TNC
+30 dBm/1W Out (Max.)
–30 dBm Input (Max.)
LAN
10-Base-T
IP/Ethernet Port
No IP Address–Endpoint
Bridge Only
COM2
DCE (Connects to serial data equip
.)
115,200 bps/8N1
Full Handshaking
RS/EIA-232