Specifications

05-4055A01, Rev. D GE MDS entraNET Reference Manual 115
Optional arguments:
SAME—Restarts the radio with the active firmware image
OTHER—Restarts the radio with the inactive image
APP1—Restarts the radio with Application Image 1
APP2—Restarts the radio with Application Image 2
SLEEP Sets or displays the low-power operating mode. These modes are com-
monly used where power consumption must be kept to a minimum, such
as in solar-powered installations.
Optional arguments:
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
DTRSENSE=<low, high>—Select the level of RS-232 DTR signal used by
the endpoint device to wake the radio:
LOW: DTR Active LOW
HIGH: DTR Active HIGH
When WAKE is set to DTR, the radio will wake on receiving this signal
from the endpoint device.
HANGTIME=<hangtime in ms>—Minimum wake time in milliseconds
(100–60000) before returning to Low Power mode.
INDICATOR=<on|off>—Indicates whether or not the Sleep indicator LED is
active.
ON: Sleep Mode indicator is on
OFF: Sleep Mode indicator is off
MODE=<mode>—Set the mode as follows:
NONE: Normal operation; the radio does not sleep
SLEEP: Sleep mode is enabled. In this mode, the radio draws less
than 20 mA at 12 Volts. It can be brought back online (ready to
send data) within 75 milliseconds. Wake-up is accomplished by
asserting the DTR line on the COM2 port, or by the appearance
of payload data at the active
COM port.
Sleep mode also works on the Ethernet interface, except that the
endpoint device must not require Ethernet pulse signals in order
to send data. This mode is similar to a PC Ethernet port “Wake
on data” setting.