Specifications
112 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
COUNT=<integer>—Number of hand-offs that occurred.
MODE=<mode>—Sets or displays the hand-off configuration, or disables
hand-offs.
OFF: Hand-off is deactivated
ACK: The Remote hands off when ACKAVG= is below the pro-
grammed threshold ACKAVGTHRESH=.
RSSI: The remote hands off when RSSIAVG= is below the pro-
grammed threshold RSSIAVGTHRESH=.
ACKRSSI: The remote hands off when either ACKAVG= or
RSSIAVG= falls below its programmed threshold.
RSSIAVG=<RSSI -dBm>—Current RSSI average dBm. This average is
determined by sampling, as defined by RSSIAVGINT=.
RSSIAVGINT=<integer>—RSSI sampling frequency, defined as:
1: One sample every 61 hops
2: Two samples every 122 hops
4: Four samples every 244 hops
8: Eight samples every 488 hops
16: 16 samples every 976 hops
32: 32 samples every 1952 hops
64: 64 samples every 3904 hops
128: 128 samples every 7808 hops
256: 256 samples every 15616 hops
RSSIAVGTHRESH=<RSSI -dBm>—The hand-off threshold for RSSI aver-
aging (–120 dBm to –50 dBm).
HELP Lists commands supported for the current user log-in level.
LOG Sets or displays the event log information, and displays the number of
entries in the event log. Optional arguments are used to clear or display
the log.
Optional arguments:
CLEAR—Clear the event log
SHOW—Show the event log
TOTAL= —Number of event log entries in log. Read only.
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.