Specifications
106 GE MDS entraNET Reference Manual 05-4055A01, Rev. D
TXDELAY= —Sets the inter-packet delay in milliseconds (1-65535). The
minimum TXDELAY setting should be set to two times the Dwelltime set-
ting. When TXDELAY is set to less than twice the Dwelltime setting, the
measured inter-packet delay can increase up to one dwelltime (7,14, or
28 ms) period.
COM2 Sets or displays the COM2 port configuration.
Optional arguments:
BAUD=<bps>—Sets or displays baud rate setting as 1200, 2400, 4800,
9600, 19200, 38400, 57600, or 115200 bps.
BUFFER=<bytes>—Sets or displays the COM2 port maximum buffer size
(1–1500). The maximum Remote buffer size for incoming serial data is
1500 bytes. The Remote can thus buffer up to 1500 bytes of serial data
(from the RTU) before splitting the serial data into separate packets.
Each packet, when transmitted over the air to an AP, is transmitted out
of the AP local serial port as a separate packet. This parameter does not
affect serial data/packets received by the Remote over the air and trans-
mitted out of the local Remote serial port.
CMD—Displays all settable optional arguments and their current values.
You can copy this list to a text file as a record of your configuration.
DEFAULT=<mode>—Sets or displays the COM1 port default mode on
startup. DEFAULT cannot be set to DATA unless the device has been autho-
rized for serial payload.
CONSOLE—COM1 defaults to command-line mode
DATA—COM1 defaults to transparent data mode
BSP—COM1 defaults to Basic Serial Protocol mode
INT_LOOP—COM1 defaults to internal loopback mode
EXT_LOOP—COM1 defaults to external loopback mode
FLOWCTRL=<mode>—Sets or displays the transceiver hardware flow
control status.
Optional arguments:
NONE—Hardware flow control disabled
CTS_CTRL—CTS (Clear-to-Send) flow control
CTS_RTS—CTS follows RTS (Ready-to-Send) flow control
RTS_CTS—DCE RTS/CTS hardware-based flow control