Specifications

05-4055A01, Rev. D GE MDS entraNET Reference Manual 101
4.1 INTRODUCTION
Local configuration of Remote transceivers is performed through a PC
terminal connected to the COM1 port of the radio. This section explains
how to establish a console session with the Remote, and provides a com-
plete list of commands.
4.2 Programming Methods
4.2.1 Terminal Interface Mode
A PC program such as HyperTerminal may be used to establish a ter-
minal session with the Remote transceiver. The PC must be connected
to the radio via its COM1 connector. Refer to PC Connection and Log-In
Procedures on Page 37 for detailed cabling information.
TIP: The HyperTerminal communications program can be accessed on
most PCs by selecting Start > Programs > Accessories > Communications >
HyperTerminal.
The following terminal settings must be used to communicate with the
Remote transceiver:
19,200 bps data rate
8 data bits
no parity
one stop bit (8N1)
hardware flow control disabled
ANSI or VT100 emulation.
NOTE: The exact parameters given above must be used for terminal
communication. Improper settings are a common cause of
difficulty.
4.2.2 Remote Management via the AP
Several Remote parameters may be configured over the air using the AP
Management System. For more information on Remote Management
via the AP, refer to WIRELESS NETWORK MENU on Page 69.
4.3 Log-in Procedure
You must log into the radio in order to issue commands. The log-in pro-
cedure for a Remote is somewhat different than for an AP. Follow the
procedure below:
1. At the
entranet> prompt, enter login.