User guide

A-3
Appendix A – Troubleshooting
DiscPort Host Status LEDs
This table applies to DiscPort XL, DiscPort PRO and DiscPort
Towers.
No. Blinks Fault Indication Corrective Action
0 Solid red Return to vendor; unit failed
power on self-test
1 Blinking amber No network found; check
network cabling
2 Blinking amber Boot server not set; configure
DiscPort
3 Blinking amber Boot filename not set,
configure DiscPort host
4 Blinking amber Boot server not found;
configure DiscPort host
5 Blinking amber Boot filename bad or not
found. Verify that the
SYS:\LOGIN (NetWare),
or C:\[Windows NT
directory]\DISCPORT.CD
(NT) directory on boot server
has the .IMG file shown in
the Fileserver Information
dialog.
7 Blinking amber SCSI bus hung. Use the
Fileserver Information
dialog to display detailed
SCSI errors (check SCSI
cables). Select the attached
server, then select More
Info from the Tools menu.
9, 10 Blinking red Call Microtest Technical
Support