User guide
A - 5
OMNIScanner User Guide
· Measurement Resolution: 0.1dB
Return Loss
· Measures Return Loss on all four pairs from both directions using
OMNIRemote
· Frequency Range: 1.0 to 300 MHz
· Dynamic Range: 0-25dB
· Factory Calibrated to ensure measurement port match to reference
100 ohm impedance.
· Measurement accuracy: Designed to meet Level III accuracy require-
ments.
· Measurement resolution: 0.1dB
Attenuation
· Tests all four pairs using OMNI
Remote
as far end active signal injector.
· Frequency Range: 1.0 to 300 MHz
· Dynamic Range: > 80 dB
· Measurement Accuracy: Calculated per TIA error model
Accuracy: 100 MHz - 0.6 dB, 200 MHz - 0.7 dB, 300 MHz - 1.0 dB
· Measurement resolution: 0.1dB
ELFEXT (Equal Level FEXT)
· Tests from both directions using OMNI
Remote
and reports all 24 pair
combinations.
· Frequency Range: 1 to 300 MHz
· Dynamic Range: >100dB
· Measurement Accuracy: Designed to meet Level III accuracy require-
ments.
· Measurement Resolution: 0.1dB
ACR (Attenuation to Crosstalk Ratio)
· Computed for 6 pair combinations from both ends at all frequency
points from the respective pair to pair NEXT and Attenuation measure-
ments.
Bandwidth
· Computed for the link or channel under test, bandwidth indicates the
highest frequency for which the worst case pair to pair crosstalk
(NEXT) is at least 3dB less than the attenuation.