User guide
OMNIScanner User Guide
8 - 4
Running a Fiber Autotest
Some Autotests do not have a fixed loss limit. The Optical Link Budget
(OLB) is calculated based on the wavelength, the length of the cable, and
the number of connectors and splices.
OMNI
Scanner
will automatically display the SPLICES/CONNECTORS
screen if you are running an equation based Autotest (TIA 568A, ISO
11801, or 1000 Base F).
1. With the Splices: field highlighted, press ENTER. Use the é or ê arrow
key to adjust the number of splices in your link. To determine the total
number of splices, simply count all of the splices in one leg of the fiber.
OMNIScanner will assume that both legs have the same amount of splices.
2. To change the number of Connectors, use the
ê to highlight the field and press ENTER. Use the
é or ê arrow key to adjust the number of connec-
tor pairs in your link. To determine the total
number of connectors, simply count all of the
connectors in one leg of the fiber. OMNIScanner
will assume that both legs have the same amount
of connectors.
3. After editing the fields, press to run the
Autotest.
OMNI
Scanner
starts the Autotest after the number
of connectors and splices has been entered.
Note: If you are running a Two Way test, you will
be prompted to swap the fibers. (See Chapter 3 -
Setup: Fiber Test Options for further information.)
4. Swap the Launch Cable’s connectors as indicated in the graphic. Do not
disconnect the Launch Cables from the OMNI
Fiber
adapters!
5. Press to complete the Autotest.
RX
TX
RX
TX